Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/12769
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzşahin, Burak-
dc.contributor.authorGüner, Abdurrahman-
dc.date.accessioned2020-09-18T12:10:31Z-
dc.date.available2020-09-18T12:10:31Z-
dc.date.issued2020-07-15-
dc.identifier.citationÖzşahin, B. ve Güner, A. (2020). "EPS yalıtım kalıplı donatılı beton taşıyıcı duvar sistemi için tasarlanan beton bileşiminin uygunluğunun belirlenmesi üzerine bir çalışma". Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, 25(2), 903-920.tr_TR
dc.identifier.issn2148-4147-
dc.identifier.issn2148-4155-
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/1256424-
dc.identifier.urihttp://hdl.handle.net/11452/12769-
dc.description.abstractGenleştirilmiş Polistiren Sert Köpük (EPS) Yalıtım Kalıplı Donatılı Beton Taşıyıcı (EPS YKDBT) Duvar Sistemi’nde, sistemin özelikleri dikkate alınarak tasarlanan “kendiliğinden yerleşen beton” (KYB) kullanılması uygundur. Fakat KYB’nin maliyetinin yüksek olması sebebiyle EPS YKDBT duvar sisteminde KYB’nin kullanılması sistemin yapım maliyetini arttırmaktadır. Sistemin yapım maliyetini düşürmek amacıyla çalışma kapsamında EPS YKDBT duvar sistemi için “çok akıcı” kıvamda geleneksel beton bileşimi tasarlandı. EPS YKDBT duvar sistemi için tasarlanan istenir geleneksel beton bileşiminin uygunluğu, KYB ile karşılaştırılarak deneysel olarak belirlenmeye çalışıldı. Çalışma sonucu incelenen EPS YKDBT Duvarlı bina yapım sisteminde vibrasyon uygulanmadan çok akıcı kıvamda geleneksel beton bileşiminin kullanılmasının uygun olmayacağı sonucuna varıldı.tr_TR
dc.description.abstractThe self compacting concrete (SCC) designed taking into account the properties of the system is suitable for use in Expanded Polystyrene Foam Insulating Concrete Form (EPS ICF) Wall System. However, the high cost of the SCC increases construction costs. In this paper, in order to reduce the construction cost of EPS ICF Wall System, a very high workability, preferably free-flowing traditional concrete composition was designed for the system. The suitability of the concrete designed was compared experimentally with that of SCC. The results of the study suggested that the usage of a desirable very high workability or flowing consistency traditional concrete placed without vibration would not be appropriate for the EPS ICF Wall System.en_US
dc.language.isotrtr_TR
dc.publisherBursa Uludağ Üniversitesitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAtıf 4.0 Uluslararasıtr_TR
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectEPStr_TR
dc.subjectEPS YKDBT duvar sistemitr_TR
dc.subjectKendiliğinden yerleşen betontr_TR
dc.subjectİstenir betontr_TR
dc.subjectICF wall systemen_US
dc.subjectSelf compacting concreteen_US
dc.subjectDesirable concreteen_US
dc.titleEPS yalıtım kalıplı donatılı beton taşıyıcı duvar sistemi için tasarlanan beton bileşiminin uygunluğunun belirlenmesi üzerine bir çalışmatr_TR
dc.title.alternativeA study on the determination of eligibility of concrete composition designed for expanded polystyrene foam insulating concrete form wall systemen_US
dc.typeArticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.identifier.startpage903tr_TR
dc.identifier.endpage920tr_TR
dc.identifier.volume25tr_TR
dc.identifier.issue2tr_TR
dc.relation.journalUludağ Üniversitesi Mühendislik Dergisi / Uludağ University Journal of The Faculty of Engineeringtr_TR
Appears in Collections:2020 Cilt 25 Sayı 2

Files in This Item:
File Description SizeFormat 
25_2_19.pdf2.15 MBAdobe PDFThumbnail
View/Open