Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/18836
Title: Uludağ Üniversitesi’nde kemiğe implante edilen işitme cihazıyla ilk deneyimler
Other Titles: Early experiences with bone anchored hearing aid in Uludağ University
Authors: Uludağ Üniversitesi/Tıp Fakültesi/Kulak-Burun-Boğaz, Baş-Boyun Cerrahi Anabilim Dalı.
Özmen, Ömer Afşin
Basut, Oğuz
Keywords: İşitme kaybı
Hearing loss
İşitme cihazı
Hearing aid
Kemik implantı
Kronik otitis media
Konjenital dış kulak yolu atrezisi
Bone implant
Chronic otitis media
Congenital aural atresia
Issue Date: 4-Oct-2011
Publisher: Uludağ Üniversitesi
Citation: Özmen, Ö. A. ve Basut, O. vd. (2010). "Uludağ Üniversitesi’nde kemiğe implante edilen işitme cihazıyla ilk deneyimler" Uludağ Üniversitesi Tıp Fakültesi Dergisi, 36(3),111-115.
Abstract: Bu çalışmada Uludağ Üniversitesi’ndeki Kemiğe İmplante Edilen İşitme Cihazı (BAHA – “Bone Anchored Hearing Aid”) deneyiminin incelenmesi amaçlanmıştır. BAHA uygulanan ve bir yıllık takipleri tamamlanan 4 hasta geriye dönük olarak incelenmiştir. Hastaların bir tanesi pediatrik yaş grubunda ve dış kulak yolu atrezisi nedeniyle opere edilirken, diğer üç hasta erişkin ve kronik otitis media nedeniyle opere edilmişlerdir. Hastaların preoperatif hava iletim eşiği 60 ± 5 dB, kemik iletim eşiği 13± 9 dB’ydi. BAHA’lı serbest saha ortalaması ise 17±9 dB’ydi. Hastaların bir yıllık takipleri sonucu sadece bir hastada minör cilt komplikasyonu gelişmiştir. Hasta memnuniyeti ise üst düzeyde bulunmuştur. Hasta sayısı az olmakla birlikte elde edilen BAHA sonuçları gelecek için umut vericidir.
The aim of the present study was to study the experience with Bone Anchored Hearing Aid (BAHA) in Uludağ University. Four patients who underwent BAHA surgery and completed one year of follow-up were analyzed retrospectively. One of the patients was in pediatric age group and operated due to aural atresia, remaining three patients were adult and operated due to chronic otitis media. Preoperative air conduction level was 60 ± 5 dB and bone conduction threshold was 13± 9 dB. Postoperative soundfield BAHA threshold was 17±9 dB. In one year of follow-up only a minor skin reaction was encountered. Patients were highly satisfied with their BAHA. Although the number of patients was low, the results of the BAHA were encouraging.
URI: https://dergipark.org.tr/tr/download/article-file/420968
http://hdl.handle.net/11452/18836
ISSN: 1300-414X
Appears in Collections:2010 Cilt 36 Sayı 3

Files in This Item:
File Description SizeFormat 
36_3_8.pdf315.71 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons