Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/21240
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCallander, T. M. S-
dc.date.accessioned2021-07-13T07:40:00Z-
dc.date.available2021-07-13T07:40:00Z-
dc.date.issued2004-01-
dc.identifier.citationCallander, T. M. S. ve Horuz, İ. (2004). “Experimental investigation of a vapor absorption refrigeration system”. International Journal of Refrigeration-Revue Internationale Du Froid, 27(1), 10-16.en_US
dc.identifier.issn0140-7007-
dc.identifier.urihttps://doi.org/10.1016/S0140-7007(03)00119-1-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0140700703001191-
dc.identifier.urihttp://hdl.handle.net/11452/21240-
dc.description.abstractAn experimental investigation of the performance of a commercially available vapor absorption refrigeration (VAR) system is described. The natural gas-fired VAR system uses aqua-ammonia solution with ammonia as the refrigerant and water as the absorbent and has a rated cooling capacity of 10 kW. The unit was extensively modified to allow fluid pressures and temperatures to be measured at strategic points in the system. The mass flow rates of refrigerant, weak solution, and strong solution were also measured. The system as supplied incorporates air-cooled condenser and absorber units. Water-cooled absorber and condenser units were fitted to extend the VAR unit's range of operating conditions by varying the cooling water inlet temperature and/or flow rates to these units. The response of the refrigeration system to variations in chilled water inlet temperature, chilled water level in the evaporator drum, chilled water flow rate, and variable heat input are presented.en_US
dc.language.isoenen_US
dc.publisherElsevier Scienceen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectExperimental investigationen_US
dc.subjectAbsorption systemen_US
dc.subjectAmmonia-wateren_US
dc.subjectMeasurementen_US
dc.subjectPerformanceen_US
dc.subjectNatural gasen_US
dc.subjectThermodynamicsen_US
dc.subjectEngineeringen_US
dc.titleExperimental investigation of a vapor absorption refrigeration systemen_US
dc.typeArticleen_US
dc.identifier.wos000186624500002tr_TR
dc.identifier.scopus2-s2.0-0142153887tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.contributor.departmentUludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.tr_TR
dc.contributor.orcid0000-0002-5519-8136tr_TR
dc.identifier.startpage10tr_TR
dc.identifier.endpage16tr_TR
dc.identifier.volume27tr_TR
dc.identifier.issue1tr_TR
dc.relation.journalInternational Journal of Refrigeration-Revue Internationale Du Froiden_US
dc.contributor.buuauthorHoruz, İlhami-
dc.contributor.researcheridAAG-5647-2019tr_TR
dc.relation.collaborationYurt dışıtr_TR
dc.subject.wosThermodynamicsen_US
dc.subject.wosEngineering, mechanicalen_US
dc.indexed.wosSCIEen_US
dc.indexed.scopusScopusen_US
dc.wos.quartileQ1en_US
Appears in Collections:Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.