Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/21446
Title: | Application of liquid-liquid extraction and adsorption on activated carbon of the determination of different forms of metals present in edible oils |
Authors: | Kowalewska, Zofia Saraçoğlu, Sibel Uludağ Üniversitesi/Fen Edebiyat Fakültesi/Kimya Bölümü. 0000-0002-1074-3612 İzgi, Belgin Güçer, Şeref AAE-8564-2020 8130734000 36849130600 |
Keywords: | Edible oil Atomic absorption spectrometry Conostan standard Extraction Fractionation Activated carbon Atomic-absorption-spectrometry Sample Vegetable-oils Trace-elements Iron Cadmium Lead Nickel Copper Fats Chemistry |
Issue Date: | 2005 |
Publisher: | Polskie Towarzystwo Chemiczne-Polish Chemical Soc |
Citation: | Kowalewska, Z. vd. (2005). "Application of liquid-liquid extraction and adsorption on activated carbon of the determination of different forms of metals present in edible oils". Chemia Analityczna, 50(6), 1007-1019. |
Abstract: | Different analytical pre-treatment procedures for determination of metals present in edible vegetable oils have been studied. The aim of liquid-liquid extraction with inorganic acids was to separate and enrich the total amount of analytes, independently of their form. In this case similar behaviour of different analyte forms was required. In the second case the adsorption oil activated carbon was performed in order to differentiate the behaviour of particular analyte forms during fractionation. It was found that the efficiency of the liquid-liquid extraction depended on the extractant used and on extraction conditions, and, in general, it was lower for organic forms of analytes than for inorganic ones. The efficiency of the applied extraction procedures using HNO3 extractant for Fe and HCl extractant for other elements was close to 100% for all investigated forms of metals. The preconcentration allowed achieving low detection limits (0.04, 0.01, 0.01, 0,03, 0.001 and 0.006 mg kg(-1) for, Fe, Ni, Cu, Ph, Cd and As, respectively), although the most of determinations were done by applying flame atomic absorption spectrometry (As was determined by AAS coupled with hydride generation). The experiments with activated carbon have revealed very similar behaviour of either the same or similar forms of different analytes. In contrast, the behaviour of different forms of the same analyte could be very distinct. Adsorption on activated carbon seems to be a promising approach towards fractionation of metals in different types of oils. |
URI: | http://hdl.handle.net/11452/21446 |
ISSN: | 0009-2223 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.