Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/22694
Title: | Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis |
Authors: | Uludağ Üniversitesi/Tıp Fakültesi/Radyoloji Anabilim Dalı. 0000-0002-3425-0740 0000-0002-3877-8366 Algın, Oktay Hakyemez, Bahattin Parlak, Müfit AAI-2318-2021 AAG-8521-2021 23995109100 6602527239 7003589220 |
Keywords: | Aqueductal stenosis Hydrocephalus Magnetic resonance imaging MR cisternography PC cine MR Endoscopic aqueductoplasty Hydrocephalus Neurosciences & neurology Radiology, nuclear medicine & medical imaging |
Issue Date: | Feb-2010 |
Publisher: | Springer |
Citation: | Algın, O. vd. (2010). "Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis". Neuroradiology, 52(2), 99-108. |
Abstract: | In the current study, we aimed to compare the diagnostic efficacies of phase-contrast magnetic resonance imaging (PC-MRI) and three-dimensional constructive interference in steady-state (3D-CISS) sequence over detection of aqueductal stenosis (AS) on the basis of contrast-enhanced magnetic resonance cisternography (MRC). Twenty-five patients with clinically and radiologically suspected AS were examined by PC-MRI, 3D-CISS, and MRC. Axial-sagittal PC-MRI and sagittal 3D-CISS were applied to view the cerebral aqueduct. Following injection of 0.5-1 ml intrathecal gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) injection, postcontrast MRC images were obtained in three planes in early and late phases. Aqueductal patency was scored as follows: grade 0, normal; grade 1, partial narrowing; and grade 2, complete obstruction. Results of PC-MRI and 3D-CISS were compared with the findings of MRC. In PC-MRI, seven cases were assessed as grade 0, 16 cases grade 1, and two cases grade 2. As a result of 3D-CISS sequence, eight cases were evaluated as grade 0, 12 cases grade 1, and five cases grade 2. Based on MRC, nine cases were assessed as grade 0, whereas nine and seven cases were evaluated to be grades 1 and 2, respectively. Five cases that demonstrated partial patency in PC-MRI or 3D-CISS showed complete obstruction by MRC. PC-MRI is helpful in confirming the AS. However, positive flow does not necessarily exclude the existence of AS. 3D-CISS sequence provides excellent cerebrospinal fluid-to-aqueduct contrast, allowing detailed study of the anatomic features of the aqueduct. MRC should be performed on patients who demonstrate suspected AS findings on PC-MRI and/or 3D-CISS sequences. |
URI: | https://doi.org/10.1007/s00234-009-0592-x https://link.springer.com/article/10.1007/s00234-009-0592-x http://hdl.handle.net/11452/22694 |
ISSN: | 0028-3940 1432-1920 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.