Title: | Treatment of recurrent tracheo-oesophageal fistula in an infant using bronchoscopic application of fibrin glue |
Authors: | Uludağ Üniversitesi/Tıp Fakültesi/Çocuk Cerrahisi Anabilim Dalı. Kılıç, Nizamettin Gürpınar, Arif Nuri Kiriştioğlu, İrfan Türkel, Turgut Doğruyol, Hasan 7005266570 7004350616 21645753900 6507091203 7003752033 |
Keywords: | Surgery Recurrent tracheo-oesophageal fistula Fibrin glue Tracheoesophageal fistula Endoscopic closure |
Issue Date: | 1999 |
Publisher: | Taylor & Francis |
Citation: | Kılıç, N. vd. (1999). "Treatment of recurrent tracheo-oesophageal fistula in an infant using bronchoscopic application of fibrin glue". Minimally Invasive Therapy & Allied Technologies, 8(2), 109-110. |
Abstract: | Recurrent tracheo-oesophageal fistula (TEF) is the most common and serious complication of the treatment of oesophageal atresia with TEF. Following this complication, the patient might need several operations. In this study, the authors report on the treatment of recurrent TEF using bronchoscopic application of fibrin glue (FG) to the fistula tract. |