Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/24018
Title: Serial changes in circulating M30 antigen, a biomarker of apoptosis, in patients with acute coronary syndromes: Relationship with the severity of coronary artery disease
Authors: Uludağ Üniversitesi/Tıp Fakültesi/Kardiyoloji Bölümü.
Uludağ Üniversitesi/Tıp Fakültesi/İç Hastalıkları Anabilim Dalı.
Uludağ Üniversitesi/Tıp Fakültesi/Biyokimya Anabilim Dalı.
0000-0003-0463-6818
0000-0002-8974-8837
0000-0003-4518-5283
Şentürk, Tunay
Aydınlar, Ali
Yılmaz, Yusuf
Oral, Arzu Yılmaztepe
Özdabakoğlu, Osman
Ulukaya, Engin
A-5841-2017
AAI-6632-2021
K-6651-2012
K-5792-2018
C-1517-2017
8342098300
6603131517
22936014300
26425326300
25221805700
6602927353
Keywords: Acute coronary syndrome
Apoptosis
Coronary artery disease
Cytokeratin 18
Acute myocardial-infarction
Cell-death
Heart-disease
Cytokeratin-18
Activation
Markers
Cardiovascular system & cardiology
Issue Date: Dec-2009
Publisher: Lippincott Williams & Wilkins
Citation: Şentürk, T. vd. (2009). "Serial changes in circulating M30 antigen, a biomarker of apoptosis, in patients with acute coronary syndromes: Relationship with the severity of coronary artery disease". Coronary Artery Disease, 20(8), 494-498.
Abstract: Objectives Growing evidence has indicated the potential clinical usefulness of measuring different forms of cytokeratin 18 in patient sera (M30 antigen for apoptosis and M65 antigen for necrosis) for distinguishing different forms of cell death. Preliminary data have reported altered levels of cytokeratin 18 fragments in patients with acute coronary syndrome (ACS) and ischemic heart disease. In this study, serum levels of M30 and M65 were measured in 74 patients with ACS [including 17 cases with unstable angina and 57 patients with acute myocardial infarction (AMI)], 25 patients with stable angina, and 23 controls. Methods In patients with ACS, serial measurements of M30 and M65 were obtained, and for each patient, the following values were determined: (i) values at admission, (ii) values obtained 24 h after symptom onset, and (iii) values obtained at 48 h after symptom onset. The severity of coronary atherosclerosis was expressed using the Gensini score. Results On admission, M30 and M65 levels in ACS patients were similar to those observed in stable angina patients and control participants. In AMI patients, serum levels of M30 peaked at 24 h and declined thereafter at 48 h. Notably, serum levels of M30 measured at 24 h correlated significantly and positively with the extent of coronary artery disease as measured by the Gensini score in AMI patients (r = 0.253, P < 0.05). Conclusion Serum levels of the apoptotic marker M30 peak at 24 h after AMI and reflects the extent of coronary artery disease in this patient group.
URI: https://doi.org/10.1097/MCA.0b013e328330d56a
https://journals.lww.com/coronary-artery/Fulltext/2009/12000/Serial_changes_in_circulating_M30_antigen,_a.2.aspx
http://hdl.handle.net/11452/24018
ISSN: 0954-6928
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.