Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/24381
Full metadata record
DC FieldValueLanguage
dc.date.accessioned2022-02-08T12:38:42Z-
dc.date.available2022-02-08T12:38:42Z-
dc.date.issued2010-
dc.identifier.citationYalçınbayır, Ö. vd. (2010). "A clinical comparison of dynamic contour tonometry versus goldmann applanation tonometry". Ophthalmic Surgery Lasers and Imaging, 41(4), 437-442.en_US
dc.identifier.issn1542-8877-
dc.identifier.issn1938-2375-
dc.identifier.urihttps://doi.org/10.3928/15428877-20100426-01-
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/20438047/-
dc.identifier.urihttp://hdl.handle.net/11452/24381-
dc.description.abstractBACKGROUND AND OBJECTIVE: To compare the intraocular pressures (IOP) obtained with dynamic contour tonometry (DCT) and Goldmann applanation tos.nometry (GAT) and to determine the dependency of both devices on corneal structure. PATIENTS AND METHODS: One hundred forty eyes of 70 patients were included. Cases with corneal pathologies, former glaucoma diagnosis, and systemic diseases were excluded. All eyes underwent measurements of central corneal thickness (CCT) and corneal curvature. IOP measurements were obtained with GAT and DCT. The agreement of measurements was statistically analyzed. RESULTS: The correlation of IOP values obtained with DCT and GAT was statistically significant. The mean DCT values were 0.46 +/- 2.55 mm Hg higher than those of GAT, but this difference was statistically insignificant. Bland-Altman plots showed reasonable inter-method agreement between DCT and GAT measurements. GAT readings were significantly affected by CCT, but DCT measurements were affected by age and corneal curvature. CONCLUSION: DCT is a reliable method of assessing IOP and is less dependent on central corneal thickness. This new technology may be a promising step forward in the management of glaucoma. Further studies are required to validate these observationen_US
dc.language.isoenen_US
dc.publisherSlacken_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCentral corneal thicknessen_US
dc.subjectOcular pulse amplitudeen_US
dc.subjectIntraocular-pressureen_US
dc.subjectHealthy-subjectsen_US
dc.subjectGlaucomaen_US
dc.subjectHypertensionen_US
dc.subjectEyesen_US
dc.subjectOphthalmologyen_US
dc.subjectSurgeryen_US
dc.subject.meshAdulten_US
dc.subject.meshAgeden_US
dc.subject.meshCorneaen_US
dc.subject.meshCross-sectional studiesen_US
dc.subject.meshFemaleen_US
dc.subject.meshGlaucomaen_US
dc.subject.meshHumansen_US
dc.subject.meshIntraocular pressureen_US
dc.subject.meshMaleen_US
dc.subject.meshMiddle ageden_US
dc.subject.meshProspective studiesen_US
dc.subject.meshReference valuesen_US
dc.subject.meshReproducibility of resultsen_US
dc.subject.meshTonometry, ocularen_US
dc.titleA clinical comparison of dynamic contour tonometry versus goldmann applanation tonometryen_US
dc.typeArticleen_US
dc.identifier.wos000280177900006tr_TR
dc.identifier.scopus2-s2.0-77955877131tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı.tr_TR
dc.relation.bapT-2005/8tr_TR
dc.identifier.startpage437tr_TR
dc.identifier.endpage442tr_TR
dc.identifier.volume41tr_TR
dc.identifier.issue4tr_TR
dc.relation.journalOphthalmic Surgery Lasers and Imagingen_US
dc.contributor.buuauthorYalçınbayır, Özgür-
dc.contributor.buuauthorBaykara, Mehmet-
dc.contributor.buuauthorAtasoy, Aydın-
dc.contributor.buuauthorÖzçetin, Hikmet-
dc.contributor.researcheridABI-7051-2020tr_TR
dc.contributor.researcheridAAH-6625-2021tr_TR
dc.identifier.pubmed20438047tr_TR
dc.subject.wosOphthalmologyen_US
dc.subject.wosSurgeryen_US
dc.indexed.wosSCIEen_US
dc.indexed.scopusScopusen_US
dc.indexed.pubmedPubmeden_US
dc.wos.quartileQ4en_US
dc.contributor.scopusid8702056700tr_TR
dc.contributor.scopusid23093006700tr_TR
dc.contributor.scopusid45360963500tr_TR
dc.contributor.scopusid6603402155tr_TR
dc.subject.scopusIntraocular Pressure; Tonometry; Keratoconusen_US
dc.subject.emtreeAdulten_US
dc.subject.emtreeAgeden_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeClinical assessmenten_US
dc.subject.emtreeControlled studyen_US
dc.subject.emtreeCornea curvatureen_US
dc.subject.emtreeCornea thicknessen_US
dc.subject.emtreeCorrelation analysisen_US
dc.subject.emtreeDynamic contour tonometryen_US
dc.subject.emtreeFemaleen_US
dc.subject.emtreeGlaucomaen_US
dc.subject.emtreeGoldmann applanation tonometryen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeIntermethod comparisonen_US
dc.subject.emtreeIntraocular pressureen_US
dc.subject.emtreeMajor clinical studyen_US
dc.subject.emtreeMaleen_US
dc.subject.emtreeMeasurementen_US
dc.subject.emtreeOutcome assessmenten_US
dc.subject.emtreePriority journalen_US
dc.subject.emtreeReliabilityen_US
dc.subject.emtreeStatistical significanceen_US
dc.subject.emtreeTonometryen_US
dc.subject.emtreeVisual acuityen_US
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.