Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/24629
Title: Ventilation rates in large commercial layer hen houses with two-year continuous monitoring
Authors: Chai, Lilong
Ni, Ji Qin
Diehl, Claude A.
Heber, Albert J.
Chen, Yan
Cortus, Erin L.
Bogan, Bill W.
Lim, Tengteeh
Ramirez-Dorronsoro, Juan Carlos
Chen, Lide
Uludağ Üniversitesi/Ziraat Fakültesi/Biyosistem Mühendisliği Bölümü.
0000-0003-0087-6718
Kılıç, İlker
AAG-8511-2021
55156382800
Keywords: Agriculture
Emissions
Ammonia
Manure
Farms
Environment
Buildings
Quality
Methane
Welfare
Issue Date: 2012
Publisher: Taylor & Francis
Citation: Chai, L. vd. (2012). "Ventilation rates in large commercial layer hen houses with two-year continuous monitoring". British Poultry Science, 53(1), 19-31.
Abstract: 1. Ventilation controls the indoor environment and is critical for poultry production and welfare. Ventilation is also crucial for assessing aerial pollutant emissions from the poultry industry. Published ventilation data for commercial layer houses have been limited, and are mostly based on short-term studies, mainly because monitoring airflow from large numbers of fans is technically challenging. 2. A two-year continuous ventilation monitoring trial was conducted at two commercial manure belt houses (A and B), each with 250 000 layers and 88 130-cm exhaust fans. All the fans were individually monitored with fan rotational speed sensors or vibration sensors. Differential static pressures across the house walls were also measured. Three fan performance assessment methods were applied periodically to determine fan degradations. Fan models were developed to calculate house ventilations. 3. A total of 693 and 678 complete data days, each containing >16 h of valid ventilation data, were obtained in houses A and B, respectively. The two-year mean ventilation rates of houses A and B were 2.08 and 2.10 m(3) h(-1) hen(-1), corresponding to static pressures of -36.5 and -48.9 Pa, respectively. For monthly mean ventilation, the maximum rates were 4.87 and 5.01 m(3) h(-1) hen(-1) in July 2008, and the minimum were 0.59 and 0.81 m(3) h(-1) hen(-1) in February 2008, for houses A and B, respectively. 4. The two-year mean ventilation rates were similar to those from a survey in Germany and a 6-month study in Indiana, USA, but were much lower than the 8.4 and 6.2 m(3) h(-1) hen(-1) from a study in Italy. The minimum monthly mean ventilation rates were similar to the data obtained in winter in Canada, but were lower than the minimum ventilation suggested in the literature. The lower static pressure in house B required more ventilation energy input. The two houses, although identical, demonstrated differences in indoor environment controls that represented potential to increase ventilation energy efficiency, and reduce carbon footprints and operational costs.
URI: https://doi.org/10.1080/00071668.2011.643766
https://www.tandfonline.com/doi/full/10.1080/00071668.2011.643766
https://pubmed.ncbi.nlm.nih.gov/22404801/
http://hdl.handle.net/11452/24629
ISSN: 0007-1668
1466-1799
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.