Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/24839
Title: Determination of trans-1,3-pentadiene in foods due to the presence of sorbic acid using SPME-GC-MS
Authors: Uludağ Üniversitesi/Ziraat Fakültesi/Gıda Mühendisliği Bölümü.
0000-0001-7871-1628
Gürbüz, Ozan
G-9316-2015
8528582100
Keywords: Chemistry
Instruments & instrumentation
GC-MS-SIM
GC-olfactometry
Sorbic acid
Trans-1,3-pentadiene
Solid-phase microextraction
Gas-chromatography
Mass-spectrometry
Yeasts
1,3-Pentadiene
Volatiles
Olives
Gas chromatography
Mass spectrometry
Volatile organic compounds
Commercial foods
Concentration levels
Food industries
Food matrixes
Food samples
Gas chromatography olfactometries
GC-MS-SIM
GC-olfactometry
Headspaces
Rapid analysis
Selective ion monitoring
Sorbates
Sorbic acid
SPME-GC-MS
Standard method
Trans-1,3-pentadiene
Volatile compounds
Carboxylic acids
Issue Date: 2011
Publisher: Taylor & Francis
Citation: Gürbüz, O. vd. (2011). "Determination of trans-1,3-pentadiene in foods due to the presence of sorbic acid using SPME-GC-MS". Instrumentation Science and Technology, 39(5), 432-446.
Abstract: The concentrations of trans-1,3-pentadiene and sorbic acid in 22 packaged commercial food samples were investigated quantitatively by gas chromatography with mass spectrometry detection in the selective ion monitoring mode (GC-MS-SIM). Gas chromatography olfactometry (GC-O) was utilized to determine detection and odor activity values for trans-1,3-pentadiene and sorbic acid. Concentration levels of trans-1,3-pentadiene ranged from 5 +/- 0.1 to 4798 +/- 14.6 mg/L on a DB5 column. Ranges for sorbic acid were from 80 +/- 0.1 to 5150 +/- 20.9 mg/L. GC-O results indicated perception of trans-1,3-pentadiene standard at 500 mg/L (gasoline, kerosene odor). Trans-1,3-pentadiene was often masked by other volatile compounds found in the various food matrixes, which eluted at the same time. GC-MS-SIM determined the quantitative analysis of trans-1,3-pentadiene. The compound was not detected in samples that lacked a sorbate preservative. The presence of trans-1,3-pentadiene in commercial foods was found in samples due to the use of a sorbate preservative. The technique for the estimation of sorbic acid and trans-1,3-pentadiene levels in the examined food samples by external standard method was applied in this study and permitted an analysis useful for the food industry. Using head space SPME and GC-MS-SIM provided a selective and rapid analyses of sorbate and trans-1,3-pentadiene simultaneously in a small amount of sample, with acceptable linearity and repeatability.
URI: https://doi.org/10.1080/10739149.2011.601386
https://www.tandfonline.com/doi/full/10.1080/10739149.2011.601386
http://hdl.handle.net/11452/24839
ISSN: 1073-9149
1525-6030
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.