Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/25051
Title: | Evaluation of ISO 6579 and FDA-BAM methods to complement real-time polymerase Chain reaction for the detection of salmonella in naturally contaminated poultry meat and red meat |
Authors: | Uludağ Üniversitesi/Veterinerlik Fakültesi/Gıda Hijyeni ve Teknolojisi Bölümü. Uludağ Üniversitesi/Veterinerlik Fakültesi/Klinik Öncesi Bilimler Bölümü. Eyigör, Ayşegül Temelli, Seran Çarlı, Kamil Tayfun AAI-1101-2021 AAI-1092-2021 E-3867-2010 6602558950 6506404118 6601971539 |
Keywords: | Internal amplification control Listeria-monocytogenes Enrichment step Rapid detection Culture method PCR SPP Enterica Assays Elisa Food science & technology Salmonella |
Issue Date: | Aug-2010 |
Publisher: | Mary Ann Liebert |
Citation: | Eyigör, A. vd. (2010). "Evaluation of ISO 6579 and FDA-BAM methods to complement real-time polymerase Chain reaction for the detection of salmonella in naturally contaminated poultry meat and red meat". Foodborne Pathogens and Disease, 7(8), 921-927. |
Abstract: | In this study, we evaluated the Salmonella detection capability and compatibility of a LightCycler polymerase chain reaction (LC PCR) system with two bacteriological methods, United States Food and Drug Administration's Bacteriological Analytical Manual Chapter 5: Salmonella (FDA) and International Organization for Standardization Method 6579 (ISO). The aim was to determine which bacteriological method would support LC PCR for testing naturally contaminated poultry and red meat samples with Salmonella. Twenty three (50.0%) and 24 (52.2%) out of 46 chicken meat samples were positive for Salmonella by the FDA and ISO methods, respectively. Five of the 15 (33.3%) turkey meat samples were found to harbor Salmonella by both bacteriological methods. None of the red meat samples were positive for Salmonella using the FDA method. There was one red meat sample (3.3%) positive for Salmonella using ISO method. LC PCR results indicated that 23 (50.0%) and 31 (67.4%) of the DNA templates obtained from the 46 preenriched chicken meat FDA and ISO samples were positive for Salmonella. Salmonella detection rate from turkey meat samples by ISO LC PCR was 6.7%, whereas no detection was observed by FDA LC PCR. FDA LC PCR detection rate in red meat samples was 23.3%, whereas the ISO LC PCR was 43.3%. Relative accuracy rates of ISO LC PCR and FDA LC PCR were 67.4%, 60.0%, 53.3% and 56.5%, 66.7%, 76.7% for chicken, turkey, and red meats, respectively. We presume that the low relative accuracy problem, which can be related to the use of FDA and ISO preenrichments for template preparations in the PCRs, can be overcome by the use of primary enrichments of both FDA and ISO bacteriologies. |
URI: | https://doi.org/10.1089/fpd.2009.0497 https://www.liebertpub.com/doi/10.1089/fpd.2009.0497 http://hdl.handle.net/11452/25051 |
ISSN: | 1535-3141 1556-7125 |
Appears in Collections: | PubMed Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.