Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/25201
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pourdeyhimi, Behnam | - |
dc.date.accessioned | 2022-03-21T06:45:29Z | - |
dc.date.available | 2022-03-21T06:45:29Z | - |
dc.date.issued | 2005-03 | - |
dc.identifier.citation | Ulcay, Y. ve Pourdeyhimi, B. (2005). "Effect of dilation on the mechanical characterization of vascular prostheses". Fibers and Polymers, 6(1), 49-54. | en_US |
dc.identifier.issn | 1229-9197 | - |
dc.identifier.issn | 1875-0052 | - |
dc.identifier.uri | https://doi.org/10.1007/BF02875573 | - |
dc.identifier.uri | https://link.springer.com/article/10.1007%2FBF02875573 | - |
dc.identifier.uri | http://hdl.handle.net/11452/25201 | - |
dc.description.abstract | The purpose of this study has been to investigate the effect of dilation on the some mechanical properties of several types of warp-knitted vascular grafts. The structures of warp knit vascular grafts used in the experiments were reverse locknit, locknit, and Tricot. Various mechanical properties of these grafts were determined using devices developed for the purpose. Clinical data obtained were compared with experimental results of warp knit vascular grafts. The most important mechanical properties are found to be creep extension, bursting strengths, and compliance. Preliminary results indicate that vascular grafts are non-compliant and exhibit creep which is predictive of the long term dilation that has been noted in the clinical results. It is found that there is a positive correlation between experimental data and clinical results for at least the grafts tested. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Korean Fiber Society | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Materials science | en_US |
dc.subject | Polymer science | en_US |
dc.subject | Vascular grafts | en_US |
dc.subject | Creep | en_US |
dc.subject | Compliance | en_US |
dc.subject | In vitro test | en_US |
dc.subject | Grafts | en_US |
dc.subject | Computer software | en_US |
dc.subject | Data acquisition | en_US |
dc.subject | Digital to analog conversion | en_US |
dc.subject | Fatigue of materials | en_US |
dc.subject | Compliance | en_US |
dc.subject | Vascular prostheses | en_US |
dc.subject | Prosthetics | en_US |
dc.title | Effect of dilation on the mechanical characterization of vascular prostheses | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000228424000008 | tr_TR |
dc.identifier.scopus | 2-s2.0-21644486589 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Tekstil Mühendisliği Bölümü. | tr_TR |
dc.identifier.startpage | 49 | tr_TR |
dc.identifier.endpage | 54 | tr_TR |
dc.identifier.volume | 6 | tr_TR |
dc.identifier.issue | 1 | tr_TR |
dc.relation.journal | Fibers and Polymers | en_US |
dc.contributor.buuauthor | Ulcay, Yusuf | - |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.subject.wos | Materials science, textiles | en_US |
dc.subject.wos | Polymer science | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q1 (Materials science, textiles) | en_US |
dc.wos.quartile | Q3 (Polymer science) | en_US |
dc.contributor.scopusid | 6601918936 | tr_TR |
dc.subject.scopus | Endoleak; Blood Vessel Prostheses; False Aneurysm | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.