Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/25703
Title: | Thermal environmental control of high-rise layer houses in California |
Authors: | Lin, Xing-Jun Cortus, Erin L. Zhang, Ruihong Jiang, Shumei Heber, Albert J. Uludağ Üniversitesi/Ziraat Fakültesi/Biyosistem Mühendisliği Bölümü. 0000-0003-0087-6718 Kılıç, İlker AAG-8511-2021 55156382800 |
Keywords: | Agriculture Airflow rate Differential static pressure Fan curve FANS FRS House temperature Humidity ratioInlet temperature Laying hens Model Uncertainty Ventilation rates Buildings California United states Environmental management Fans Floors Fog dispersal Manures Models Structural design Ventilation Air flow-rate Fan curves Humidity ratio Inlet temperature Static pressure Uncertainty Air temperature Airflow Atmospheric pollution Humidity Multistorey building Performance assessment Poultry Pressure gradient Spatiotemporal analysis Temperature effect Uncertainty analysis Houses |
Issue Date: | 2012 |
Publisher: | Amer Soc Agricultural & Biological Engineers |
Citation: | Lin, X. J. vd. (2012). "Thermal environmental control of high-rise layer houses in California". Transactions of the ASABE, 55(5), 1909-1920. |
Abstract: | The ventilation systems of two high-rise layer houses in California were monitored from 10/25/07 to 10/31/09 (m/d/y) for the National Air Emission Monitoring Study to facilitate the calculation of air pollutant emission rates. The ventilation systems, building structural design, feeding systems, and manure management practices of the houses were identical. Each house had approximately 32,500 laying hens in cages on the second floor (layer room) and was mechanically ventilated in cross-flow fashion with 12 sidewall single-speed exhaust fans on the first floor, consisting of two 91 cm fans and ten 122 cm fans. The fan rotational speeds, differential static pressure, temperature, relative humidity, and the evaporative misting system of each house and outside weather variables were continuously monitored. All 24 fans were evaluated with a portable fan tester three times during the two-year test. Fan airflow models were developed from in situ fan test data to calculate the fan airflow rates based on house differential static pressure and fan rotational speeds. The results showed that the fan performance factors of the 91 cm and 122 cm fans were 75% and 84% of the airflows, respectively, of new unused fans. The daily mean dry standard house ventilation rate averaged 47 m(3) s(-1) at dry standard conditions and ranged from 12 to 88 m(3) s(-1). The daily mean hen-specific ventilation rates averaged 5 m(3) h(-1) hen(-1) and ranged from 1.3 to 9.8 m(3) h(-1) hen(-1). Relative uncertainties of the hourly mean hen-specific ventilation rates averaged +/- 4.8% and ranged from +/- 2.9% to +/- 8.8%. The house differential static pressures ranged from -35 to -10 Pa 92% of the time. The layer room temperatures were controlled by adjusting the ventilation rate, which generally increased with ambient temperature. The evaporative misting system decreased the layer room temperature by up to 8 degrees C from the ambient, or barn inlet, air temperature while contributing to an increase of up to 3.8 g kg(-1) in the house humidity ratio relative to barn inlet conditions. |
URI: | https://doi.org/10.13031/2013.42353 https://elibrary.asabe.org/abstract.asp?aid=42353 https://ur.booksc.eu/book/84862196/3a1409 http://hdl.handle.net/11452/25703 |
ISSN: | 2151-0032 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.