Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/25876
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Motorcu, Ali Rıza | - |
dc.date.accessioned | 2022-04-20T06:11:15Z | - |
dc.date.available | 2022-04-20T06:11:15Z | - |
dc.date.issued | 2012-06 | - |
dc.identifier.citation | Coşkun, S. vd. (2012). "Evaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump". International Journal of Refrigeration, 35(4), 795-809. | en_US |
dc.identifier.issn | 0140-7007 | - |
dc.identifier.issn | 1879-2081 | - |
dc.identifier.uri | https://doi.org/10.1016/j.ijrefrig.2011.12.008 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0140700711003094 | - |
dc.identifier.uri | http://hdl.handle.net/11452/25876 | - |
dc.description.abstract | This paper deals with an investigation of the effect and optimization of control parameters on the system performance in waste heat recovery application using mechanical heat pump (MHP). The experimental studies have been conducted under varying compressor speed, wastewater temperature and flow rate. The experiments have been planned based on Taguchi's L27 orthogonal array with each trial performed under different conditions of compressor's speed, wastewater temperature and flow rate. The optimum parameter combination has been obtained by using the analysis of signal-to-noise (S/N) ratio. The level of importance of the control parameters on the system performance has been determined by using analysis of variance (ANOVA). Main effects plots and interaction effects plots have been utilized to optimize and analyze the relation between the control parameters and the system performance. The results obtained from Taguchi method were also compared with ANN results. The experimental study indicated that it is possible to increase system performance significantly in the waste heat recovery application using MHP. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Thermodynamics | en_US |
dc.subject | Engineering | en_US |
dc.subject | Heat pump | en_US |
dc.subject | Heat recovery | en_US |
dc.subject | Mechanical vapor compression | en_US |
dc.subject | Wastewater | en_US |
dc.subject | Waste heat | en_US |
dc.subject | Taguchi | en_US |
dc.subject | Optimum working-conditions | en_US |
dc.subject | Industry | en_US |
dc.subject | Optimization | en_US |
dc.subject | Flow rate | en_US |
dc.subject | Heat pump systems | en_US |
dc.subject | Taguchi methods | en_US |
dc.subject | Vapors | en_US |
dc.subject | Control parameters | en_US |
dc.subject | Experimental studies | en_US |
dc.subject | Heat pumps | en_US |
dc.subject | Interaction effect | en_US |
dc.subject | Main effect | en_US |
dc.subject | Mechanical vapor compressions | en_US |
dc.subject | Optimum parameters | en_US |
dc.subject | Orthogonal array | en_US |
dc.subject | Signal to noise (S/N) ratios | en_US |
dc.subject | Wastewater temperature | en_US |
dc.subject | Waste heat utilization | en_US |
dc.title | Evaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000305655300007 | tr_TR |
dc.identifier.scopus | 2-s2.0-84861226963 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/Elektrik ve Enerji Bölümü. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü. | tr_TR |
dc.relation.bap | M-2008/63 | tr_TR |
dc.identifier.startpage | 795 | tr_TR |
dc.identifier.endpage | 809 | tr_TR |
dc.identifier.volume | 35 | tr_TR |
dc.identifier.issue | 4 | tr_TR |
dc.relation.journal | International Journal of Refrigeration | en_US |
dc.contributor.buuauthor | Coşkun, Salih | - |
dc.contributor.buuauthor | Yamankaradeniz, Nurettin | - |
dc.contributor.buuauthor | Pulat, Erhan | - |
dc.contributor.researcherid | AAA-1753-2021 | tr_TR |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.subject.wos | Thermodynamics | en_US |
dc.subject.wos | Engineering, mechanical | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q1 (Engineering, mechanical) | en_US |
dc.wos.quartile | Q2 (Thermodynamics) | en_US |
dc.contributor.scopusid | 26644674500 | tr_TR |
dc.contributor.scopusid | 26645227400 | tr_TR |
dc.subject.scopus | Liquid Sodium; Sodium-cooled Fast Reactors; Core Disruptive Accidents | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.