Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/26396
Title: | Yüksek dansiteli lipoprotein-kolesterol tayininde dekstran sülfat-magnezyum ve fosfotungstat-magnezyum presipitasyon tekniklerinin incelenmesi |
Other Titles: | Evaluation of dextran sulphate-magnesium and phosphotungstate-magnesium precipitation techniques for high density lipoprotein-cholesterol determination |
Authors: | Uludağ Üniversitesi/Tıp Fakültesi/Biyokimya Anabilim Dalı. Dirican, Melahat Sarandöl, Emre Ulukaya, Engin Tokullugil, Asuman |
Keywords: | Yüksek dansiteli lipoprotein-kolesterol Lipoprotein presipitasyonu High density lipoprotein-cholesterol Lipoprotein precipitation |
Issue Date: | 29-Nov-1995 |
Publisher: | Uludağ Üniversitesi |
Citation: | Dirican, M. vd. (1995). ''Yüksek dansiteli lipoprotein-kolesterol tayininde dekstran sülfat-magnezyum ve fosfotungstat-magnezyum presipitasyon tekniklerinin incelenmesi''. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 22(1-2-3), 41-45. |
Abstract: | Normal sağlıklı kişilerden (n=50) elde edilen serumlarda farklı tekniklerle yüksek dansiteli lipoprotein kolesterol (HDL-K) tayini yapıldı: 1- Dekstran sülfat-magnezyum (DS-Mg) presipitasyon, enzimatik yöntemle kolesterol ölçümü (EDS), 2-DS-Mg presipitasyon, kimyasal yöntemle (Zak) kolesterol ölçümü (ZDS), 3- Fosfotungstat-Mg (FT-Mg) presipitasyonu, enzimatik yöntemle kolesterol ölçümü (EFT), 4-FT-Mg presipitasyonu, kimyasal yöntemle kolesterol ölçümü (ZFT). Dört değişik şekilde ölçülen HDL-K düzeylerinin birbirlerinden anlamlı şekilde farklı oldukları ancak, aralarında anlamlı düzeyde korelasyon gösterdikleri saptandı. En yüksek korelasyon (r=0. 705) EFT ile ZDS yöntemleri arasında bulundu. Çalışma-içi değişkenlik katsayısı(% CV) EDS, ZDS, EFT ve ZFT için normal havuzda sırasıyla 9. 71, 5.23, 7.38, 3.69; yüksek havuzda 12.15, 15.36, 10.12 ve 6.20 idi. Günler-arası% CV +4 C'de bekletilen serumlarda, - 20 C'de bekletilenlere göre biraz daha düşük bulundu. Sonuçta, HDL-K tayininde isabet derecesinin iyi olmamasından presipitasyon işleminin sorumlu olduğu düşünüldü. High density lipoprotein-cholesterol (HDL-C) was determined in the sera of normal healthy persons (n= 50) with different techniques: 1-Precipitation with dextran sulphate-magnesium (DS-Mg), enzymatically choleste of determination (EDS), 2-Precipitation with DS-Mg, chemically (Zak) cholesterol determination (ZDS) 3- Precipitation with phosphotungstate-Mg, enzymatically cholesterol determination (EFT), 4-Precipitation with FT-Mg, chemically cholesterol determination (ZFT). The HDL-C levels found by 4 different methods were significantly different from each other; on the other hand there were significantly correlations among each other. The highest correlation (r=O. 705) was found between EFT and ZDS nı thods. Within-run coefficient of variation (%CV) in the normal serum pool for EDS, ZDS, EFT and ZFT were 9. 71, 5.23, 7.38, 3.96; and 12.1 5, 1 5.36, 10.12, 6.2 in the high serum pool, respectively. Between-day% CV was found slightly tower in the sera kept at +4C than the sera kept at - 20C. Finally, we thought that the reason for precision not being satisfactory, is the precipiıation step. |
URI: | http://hdl.handle.net/11452/26396 |
ISSN: | 1300-414X |
Appears in Collections: | 1995 Cilt 22 Sayı 1-2-3 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
22_1-2-3_10.pdf | 1.86 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License