Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/26610
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kaplan, Tolga | - |
dc.date.accessioned | 2022-05-23T11:14:30Z | - |
dc.date.available | 2022-05-23T11:14:30Z | - |
dc.date.issued | 2012-01 | - |
dc.identifier.citation | Kaplan, T. vd. (2012). "Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures". Ulusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery, 18(1), 65-70. | tr_TR |
dc.identifier.issn | 1306-696X | - |
dc.identifier.uri | https://doi.org/10.5505/tjtes.2012.33427 | - |
dc.identifier.uri | https://tjtes.org/jvi.aspx?pdir=travma&plng=eng&volume=18&issue=1 | - |
dc.identifier.uri | http://hdl.handle.net/11452/26610 | - |
dc.description.abstract | BACKGROUND The purpose of this study was to compare the period of union, functional outcomes and complications of patients with femoral neck fracture treated with percutaneous cannulated screws versus dynamic hip screw (DHS). METHODS Sixty-six patients with femoral neck fracture were treated with percutaneous cannulated screws (n=33) or with DHS (n=33) between August 1999 and October 2003. Functional outcome was measured using Harris Hip Score, and period of union, amount of bleeding and complications were also recorded. RESULTS The period of union and functional outcomes were not different between the two groups. Risk of avascular necrosis (AVN) was associated mainly with the grade of fracture displacement. In the percutaneous cannulated screw group, duration of surgery was shorter and blood loss was less than in the other group. CONCLUSION There was no superiority between cannulated screws and DHS according to union times and functional results. Risk of AVN is related to the degree of displacement. However, a prospective randomized study is needed to determine the outcome of each technique for patients suffering similar displacement rates. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Türk Travma ve Acil Cerrahi Dergisi | tr_TR |
dc.rights | info:eu-repo/semantics/openAccess | tr_TR |
dc.rights | Atıf Gayri Ticari Türetilemez 4.0 Uluslararası | tr_TR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Emergency medicine | en_US |
dc.subject | Dynamic hip screw | en_US |
dc.subject | Fractures of the femoral neck | en_US |
dc.subject | Percutaneous | en_US |
dc.subject | Cannulated screw | en_US |
dc.subject | Intracapsular fractures | en_US |
dc.subject | Hip-fractures | en_US |
dc.subject | Proximal femur | en_US |
dc.subject | Subcapital fractures | en_US |
dc.subject | Fixation | en_US |
dc.subject | Rehabilitation | en_US |
dc.subject | Management | en_US |
dc.subject | Outcomes | en_US |
dc.subject | Sweden | en_US |
dc.subject | System | en_US |
dc.title | Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures | en_US |
dc.title.alternative | Femur boyun kırıklarının tedavisinde perkütan kanüle vida, dinamik kompresyon plak ve vidanın karşılaştırmalı sonuçları | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000300521700013 | tr_TR |
dc.identifier.scopus | 2-s2.0-84855802596 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Ortopedi ve Travmatoloji Anabilim Dalı. | tr_TR |
dc.identifier.startpage | 65 | tr_TR |
dc.identifier.endpage | 70 | tr_TR |
dc.identifier.volume | 18 | tr_TR |
dc.identifier.issue | 1 | tr_TR |
dc.relation.journal | Ulusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery | tr_TR |
dc.contributor.buuauthor | Akesen, Burak | - |
dc.contributor.buuauthor | Demirağ, Burak | - |
dc.contributor.buuauthor | Bilgen, Sadık | - |
dc.contributor.buuauthor | Durak, Kemal | - |
dc.contributor.researcherid | AAI-1638-2021 | tr_TR |
dc.contributor.researcherid | AAH-9833-2021 | tr_TR |
dc.relation.collaboration | Sanayi | tr_TR |
dc.indexed.trdizin | TrDizin | tr_TR |
dc.identifier.pubmed | 22290053 | tr_TR |
dc.subject.wos | Emergency medicine | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.pubmed | PubMed | en_US |
dc.wos.quartile | Q4 | en_US |
dc.contributor.scopusid | 23102160500 | tr_TR |
dc.contributor.scopusid | 56019156900 | tr_TR |
dc.contributor.scopusid | 15061239900 | tr_TR |
dc.contributor.scopusid | 6602850051 | tr_TR |
dc.subject.scopus | Femoral Neck Fractures; Hemiarthroplasty; Femur Neck | en_US |
dc.subject.emtree | Adult | en_US |
dc.subject.emtree | Aged | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Avascular necrosis | en_US |
dc.subject.emtree | Bleeding | en_US |
dc.subject.emtree | Bone plate | en_US |
dc.subject.emtree | Bone screw | en_US |
dc.subject.emtree | Controlled study | en_US |
dc.subject.emtree | Dynamic hip screw | en_US |
dc.subject.emtree | Female | en_US |
dc.subject.emtree | Femur neck fracture | en_US |
dc.subject.emtree | Fracture healing | en_US |
dc.subject.emtree | Harris hip score | en_US |
dc.subject.emtree | Human | en_US |
dc.subject.emtree | Intermethod comparison | en_US |
dc.subject.emtree | Internal fixator | en_US |
dc.subject.emtree | Major clinical study | en_US |
dc.subject.emtree | Male | en_US |
dc.subject.emtree | Operation duration | en_US |
dc.subject.emtree | Osteosynthesis | en_US |
dc.subject.emtree | Percutaneous cannulated screw | en_US |
dc.subject.emtree | Postoperative complication | en_US |
dc.subject.emtree | Retrospective study | en_US |
dc.subject.emtree | Treatment outcome | en_US |
Appears in Collections: | Scopus TrDizin Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Akesen_vd_2012.pdf | 3.38 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License