Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/26610
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKaplan, Tolga-
dc.date.accessioned2022-05-23T11:14:30Z-
dc.date.available2022-05-23T11:14:30Z-
dc.date.issued2012-01-
dc.identifier.citationKaplan, T. vd. (2012). "Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures". Ulusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery, 18(1), 65-70.tr_TR
dc.identifier.issn1306-696X-
dc.identifier.urihttps://doi.org/10.5505/tjtes.2012.33427-
dc.identifier.urihttps://tjtes.org/jvi.aspx?pdir=travma&plng=eng&volume=18&issue=1-
dc.identifier.urihttp://hdl.handle.net/11452/26610-
dc.description.abstractBACKGROUND The purpose of this study was to compare the period of union, functional outcomes and complications of patients with femoral neck fracture treated with percutaneous cannulated screws versus dynamic hip screw (DHS). METHODS Sixty-six patients with femoral neck fracture were treated with percutaneous cannulated screws (n=33) or with DHS (n=33) between August 1999 and October 2003. Functional outcome was measured using Harris Hip Score, and period of union, amount of bleeding and complications were also recorded. RESULTS The period of union and functional outcomes were not different between the two groups. Risk of avascular necrosis (AVN) was associated mainly with the grade of fracture displacement. In the percutaneous cannulated screw group, duration of surgery was shorter and blood loss was less than in the other group. CONCLUSION There was no superiority between cannulated screws and DHS according to union times and functional results. Risk of AVN is related to the degree of displacement. However, a prospective randomized study is needed to determine the outcome of each technique for patients suffering similar displacement rates.en_US
dc.language.isoenen_US
dc.publisherTürk Travma ve Acil Cerrahi Dergisitr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.rightsAtıf Gayri Ticari Türetilemez 4.0 Uluslararasıtr_TR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEmergency medicineen_US
dc.subjectDynamic hip screwen_US
dc.subjectFractures of the femoral necken_US
dc.subjectPercutaneousen_US
dc.subjectCannulated screwen_US
dc.subjectIntracapsular fracturesen_US
dc.subjectHip-fracturesen_US
dc.subjectProximal femuren_US
dc.subjectSubcapital fracturesen_US
dc.subjectFixationen_US
dc.subjectRehabilitationen_US
dc.subjectManagementen_US
dc.subjectOutcomesen_US
dc.subjectSwedenen_US
dc.subjectSystemen_US
dc.titleComparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fracturesen_US
dc.title.alternativeFemur boyun kırıklarının tedavisinde perkütan kanüle vida, dinamik kompresyon plak ve vidanın karşılaştırmalı sonuçlarıen_US
dc.typeArticleen_US
dc.identifier.wos000300521700013tr_TR
dc.identifier.scopus2-s2.0-84855802596tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Ortopedi ve Travmatoloji Anabilim Dalı.tr_TR
dc.identifier.startpage65tr_TR
dc.identifier.endpage70tr_TR
dc.identifier.volume18tr_TR
dc.identifier.issue1tr_TR
dc.relation.journalUlusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgerytr_TR
dc.contributor.buuauthorAkesen, Burak-
dc.contributor.buuauthorDemirağ, Burak-
dc.contributor.buuauthorBilgen, Sadık-
dc.contributor.buuauthorDurak, Kemal-
dc.contributor.researcheridAAI-1638-2021tr_TR
dc.contributor.researcheridAAH-9833-2021tr_TR
dc.relation.collaborationSanayitr_TR
dc.indexed.trdizinTrDizintr_TR
dc.identifier.pubmed22290053tr_TR
dc.subject.wosEmergency medicineen_US
dc.indexed.wosSCIEen_US
dc.indexed.scopusScopusen_US
dc.indexed.pubmedPubMeden_US
dc.wos.quartileQ4en_US
dc.contributor.scopusid23102160500tr_TR
dc.contributor.scopusid56019156900tr_TR
dc.contributor.scopusid15061239900tr_TR
dc.contributor.scopusid6602850051tr_TR
dc.subject.scopusFemoral Neck Fractures; Hemiarthroplasty; Femur Necken_US
dc.subject.emtreeAdulten_US
dc.subject.emtreeAgeden_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeAvascular necrosisen_US
dc.subject.emtreeBleedingen_US
dc.subject.emtreeBone plateen_US
dc.subject.emtreeBone screwen_US
dc.subject.emtreeControlled studyen_US
dc.subject.emtreeDynamic hip screwen_US
dc.subject.emtreeFemaleen_US
dc.subject.emtreeFemur neck fractureen_US
dc.subject.emtreeFracture healingen_US
dc.subject.emtreeHarris hip scoreen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeIntermethod comparisonen_US
dc.subject.emtreeInternal fixatoren_US
dc.subject.emtreeMajor clinical studyen_US
dc.subject.emtreeMaleen_US
dc.subject.emtreeOperation durationen_US
dc.subject.emtreeOsteosynthesisen_US
dc.subject.emtreePercutaneous cannulated screwen_US
dc.subject.emtreePostoperative complicationen_US
dc.subject.emtreeRetrospective studyen_US
dc.subject.emtreeTreatment outcomeen_US
Appears in Collections:Scopus
TrDizin
Web of Science

Files in This Item:
File Description SizeFormat 
Akesen_vd_2012.pdf3.38 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons