Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/26734
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özdemir, Levent | - |
dc.date.accessioned | 2022-05-27T12:55:56Z | - |
dc.date.available | 2022-05-27T12:55:56Z | - |
dc.date.issued | 2009-03-26 | - |
dc.identifier.citation | Özdemir, B. vd. (2009). "Aortic distensibility and coronary artery bypass graft patency". Journal of Cardiothoracic Surgery, 4,1-7. | en_US |
dc.identifier.issn | 1749-8090 | - |
dc.identifier.uri | https://doi.org/10.1186/1749-8090-4-14 | - |
dc.identifier.uri | https://cardiothoracicsurgery.biomedcentral.com/articles/10.1186/1749-8090-4-14 | - |
dc.identifier.uri | http://hdl.handle.net/11452/26734 | - |
dc.description.abstract | Background: Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determined aortic distensibility with the patency rates of coronary bypass grafts Methods: The study was conducted in the Cardiology department of the Applied Research Centre for Health of Uludag University. The coronary angiograms of 53 consecutive coronary bypass patients were analysed retrospectively. Aortic distensibility was calculated using the formula: 2 x (change in aortic diameter)/(diastolic aortic diameter) x (change in aortic pressure). The number of stenosed and patent bypass grafts and the patient characteristics like age, risk factors were noted. Results: There were 44 male (83%) and 9 female (17%) cases. Eighteen cases had only one saphenous vein grafting. The number of cases with two, three and four saphenous grafting were 18, 11 and 1; respectively. In the control angiograms the number of cases with one, two, three and four saphenous vein graft obstruction were 15 (31.3%), 7 (14.6%), 1 (2.1%) and 1 (2.1%) respectively. The aortic distensibility did not differ in cases with and without saphenous graft occlusion (p > 0.05). Also left internal mammary artery (LIMA) graft patency was not related to the distensibility of the aorta (p > 0.05). We also evaluated the data for cut-off values of 50 and 70 mmHg of pulse pressure and did not see any significant difference between the groups in terms of saphenous or LIMA grafts. Conclusion: In this study we failed to show association of angiographically determined aortic distensibility with coronary bypass graft patency in consecutive 53 patients with coronary artery bypass graft surgery (CABG). | en_US |
dc.language.iso | en | en_US |
dc.publisher | Bmc | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Atıf Gayri Ticari Türetilemez 4.0 Uluslararası | tr_TR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Saphenous-vein | en_US |
dc.subject | Ascending aorta | en_US |
dc.subject | Risk-factors | en_US |
dc.subject | Atherosclerosis | en_US |
dc.subject | Disease | en_US |
dc.subject | Surgery | en_US |
dc.subject | Association | en_US |
dc.subject | Progression | en_US |
dc.subject | Operation | en_US |
dc.subject | Stifiness | en_US |
dc.subject | Cardiovascular system & cardiology | en_US |
dc.subject | Surgery | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Aorta | en_US |
dc.subject.mesh | Aortography | en_US |
dc.subject.mesh | Blood pressure | en_US |
dc.subject.mesh | Coronary angiography | en_US |
dc.subject.mesh | Coronary artery bypass | en_US |
dc.subject.mesh | Elasticity | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Mammary arteries | en_US |
dc.subject.mesh | Middle aged | en_US |
dc.subject.mesh | Retrospective studies | en_US |
dc.subject.mesh | Saphenous vein | en_US |
dc.subject.mesh | Statistics, nonparametric | en_US |
dc.subject.mesh | Vascular patency | en_US |
dc.title | Aortic distensibility and coronary artery bypass graft patency | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000265140600001 | tr_TR |
dc.identifier.scopus | 2-s2.0-64949169302 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Kardiyoloji Anabilim Dalı. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Kalp Damar Cerrahisi Anabilim Dalı. | tr_TR |
dc.contributor.orcid | 0000-0002-8974-8837 | tr_TR |
dc.identifier.startpage | 1 | tr_TR |
dc.identifier.endpage | 7 | tr_TR |
dc.identifier.volume | 4 | tr_TR |
dc.relation.journal | Journal of Cardiothoracic Surgery | en_US |
dc.contributor.buuauthor | Özdemir, Bülent | - |
dc.contributor.buuauthor | Biçer, Murat | - |
dc.contributor.buuauthor | Baran, İbrahim | - |
dc.contributor.buuauthor | Kaderli, Aysel Aydın | - |
dc.contributor.buuauthor | Şentürk, Tunay | - |
dc.contributor.buuauthor | Emül, Ali | - |
dc.contributor.buuauthor | Yetgin, Zeynel Abidin | - |
dc.contributor.buuauthor | Güllülü, Sümeyye | - |
dc.contributor.buuauthor | Aydınlar, Ali | - |
dc.contributor.researcherid | C-1517-2017 | tr_TR |
dc.contributor.researcherid | ABC-2231-2020 | tr_TR |
dc.contributor.researcherid | AAI-6632-2021 | tr_TR |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.identifier.pubmed | 19323814 | tr_TR |
dc.subject.wos | Cardiac & cardiovascular systems | en_US |
dc.subject.wos | Surgery | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.pubmed | PubMed | en_US |
dc.wos.quartile | Q4 | en_US |
dc.contributor.scopusid | 7004168959 | tr_TR |
dc.contributor.scopusid | 6507770944 | tr_TR |
dc.contributor.scopusid | 35572557400 | tr_TR |
dc.contributor.scopusid | 7801322152 | tr_TR |
dc.contributor.scopusid | 8342098300 | tr_TR |
dc.contributor.scopusid | 23967725800 | tr_TR |
dc.contributor.scopusid | 26436271200 | tr_TR |
dc.contributor.scopusid | 57204660708 | tr_TR |
dc.contributor.scopusid | 6603131517 | tr_TR |
dc.subject.scopus | Saphenous Vein; Coronary Artery Bypass Graft; Embolic Protection Devices | en_US |
dc.subject.emtree | Aged | en_US |
dc.subject.emtree | Angiocardiography | en_US |
dc.subject.emtree | Aorta | en_US |
dc.subject.emtree | Aortography | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Blood pressure | en_US |
dc.subject.emtree | Comparative study | en_US |
dc.subject.emtree | Coronary artery bypass graft | en_US |
dc.subject.emtree | Elasticity | en_US |
dc.subject.emtree | Female | en_US |
dc.subject.emtree | Human | en_US |
dc.subject.emtree | Male | en_US |
dc.subject.emtree | Mammary artery | en_US |
dc.subject.emtree | Methodology | en_US |
dc.subject.emtree | Middle aged | en_US |
dc.subject.emtree | Nonparametric test | en_US |
dc.subject.emtree | Pathophysiology | en_US |
dc.subject.emtree | Retrospective study | en_US |
dc.subject.emtree | Saphenous vein | en_US |
dc.subject.emtree | Transplantation | en_US |
dc.subject.emtree | Vascular patency | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Özdemir_vd_2009.pdf | 1.54 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License