Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/27206
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzler, Azmi-
dc.contributor.authorGürsoy, Nihat-
dc.contributor.authorBilgen, Fuat-
dc.contributor.authorCanik, Sevim-
dc.date.accessioned2022-06-16T19:55:27Z-
dc.date.available2022-06-16T19:55:27Z-
dc.date.issued1990-
dc.identifier.citationÖzler, A. vd. (1990). ''Postrepair fallot tetralolojisi olgularında infundibuloplasti yama uzunluğu ile sağ ventrikül uzunluğu arasındaki oranın sağ ventrikül fonksiyonu üzerindeki etkisi''. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 17(2), 259-266.tr_TR
dc.identifier.urihttp://hdl.handle.net/11452/27206-
dc.description.abstractFallot tetralojisinin intrakardiak tamirinden sonra sağ ventrikül fonksiyonunun korunması, minimal ventrikülotomi ve minimal myokardial rezeksiyon ile birlikte standardize patch infundibuloplasti sayesinde mümkündür. Deneysel çalışmalar göstermiştir ki; sağ ventrikül uzunluğunun kabaca % 50'sinden daha kısa olan infundibuloplasti yaması sağ ventrikül kontraksiyonunu bozmamaktadır. Optimal infundiplasti patch uzunluğu, sağ ventrikül uzunluğunun % 30 ile % 45 arasında olduğu tesbit edilmiştir. Minimum (a/b: % 30) ve maximum (a/b: % 45) patch infundibuloplasti uzunlukları tayin edilerek bunlarla ilgili standart formüller aşağıda gösterildi[ğii gibidir. 1.28 x Vücut yüzeyi (m2 ) + 1.10 cm (Minumum a/b) ve 1.93 x Vücut yüzeyi (m2 ) + 1.65 cm (Maximum a/b) .Araştırma serimizi oluşturan toplam 40 fallot tetralojisi olgusuna total korreksiyon uygulanmıştır.Ameliyat esnasında her hastanın pulmoner annulustan itibaren, infundibuler patch (a) ve sağ ventrikül uzunluğu (b) cm. olarak ölçülmüştür. Her hastada Patch/RV (a/b) oranı tesbit edilip, postoperatif prognozu ve sonuu ne şekilde etkilediği araştırılmıştır. Sağ ventrikül uzunluğunun % 50'sinden daha uzun olan patch infundibuloplasti uygulandığında sağ ventrikül kontraksiyonu ciddi olarak bozulmaktadır.tr_TR
dc.description.abstractTo preserve right ventricular function after intracardiac repair of tetralogy of Fallot, we developed a standardized patch infundibuloplasty with minimum ventriculotomy and myocardial resection. An experimental study suggested that short length infundibuloplasty, less than 50 % of the right ventricular length, did not reduce the right ventricular function. The optimal infundibuloplasty patch length was determined to be between 30 % and 45 % of the right ventricular length. The standart formulas for determining minimum (a/b: 30 %) and maximum (a/b: 45 %) patch infundibuloplasty lengths were as follows: 1.28 x body surface area (m2 ) + 1.10 cm (minimum a/b) and 1.93 x body surface area (m2 ) + 1.65 cm (maximum a/b).Total correction has been applied to our 40 patients with tetralogy of Fallot. In each of these patients, patch infundibuloplasty length ( a) and right ventricular length (b) has been measured intraoperatievely. Patch/RV ( a/b) ratio has been calculated in all patients and the correlation between this ratio and prognosis studied. In cases where patch infundibuloplasty has been applied with right ventricular having 50 % of longer length, the contraction of right ventricular is severly reduced.tr_TR
dc.language.isotrtr_TR
dc.publisherUludağ Üniversitesitr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectPostrepair fallot tetralolojitr_TR
dc.subjectInfundibuloplasti yama uzunluğutr_TR
dc.subjectSağ ventrikül uzunluğutr_TR
dc.subjectSağ ventrikül fonksiyonutr_TR
dc.subjectPostrepair fallot tetralologytr_TR
dc.subjectRight ventricle lengthtr_TR
dc.subjectRight ventricular functiontr_TR
dc.subjectInfundibuloplasty patch lengthtr_TR
dc.subjectİnfundibuloplasti yama uzunluğutr_TR
dc.subjectPatch bifundibuloplasty lengthtr_TR
dc.titlePostrepair fallot tetralolojisi olgularında infundibuloplasti yama uzunluğu ile sağ ventrikül uzunluğu arasındaki oranın sağ ventrikül fonksiyonu üzerindeki etkisitr_TR
dc.title.alternativeIn the patients with postrepair tetralogy of fallot, the effect on the right ventricular function of ratio of patch infundibuloplasty length to right ventricular lengthtr_TR
dc.typeArticletr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.identifier.startpage259tr_TR
dc.identifier.endpage266tr_TR
dc.identifier.volume17tr_TR
dc.identifier.issue2tr_TR
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisitr_TR
Appears in Collections:1990 Cilt 17 Sayı 2

Files in This Item:
File Description SizeFormat 
17_2_5.pdf1.56 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons