Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/28911
Tüm üstveri kaydı
Dublin Core AlanıDeğerDil
dc.contributor.authorSoykok, İbrahim Fadil-
dc.contributor.authorSayman, Onur-
dc.contributor.authorÖzen, Mustafa-
dc.date.accessioned2022-09-30T12:33:55Z-
dc.date.available2022-09-30T12:33:55Z-
dc.date.issued2013-02-
dc.identifier.citationSoykok, İ. F. (2013). "Failure analysis of mechanically fastened glass fiber/epoxy composite joints under thermal effects". Composites Part B-Engineering, 45(1), 192-199.en_US
dc.identifier.issn1359-8368-
dc.identifier.issn1879-1069-
dc.identifier.urihttps://doi.org/10.1016/j.compositesb.2012.08.008-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1359836812005148-
dc.identifier.urihttp://hdl.handle.net/11452/28911-
dc.description.abstractAn experimental failure analysis has been carried out to determine the effects of thermal condition and tightening torque on the failure load and failure behavior of single lap double serial fastener glass fiber/epoxy composite joints. 40, 50, 60, 70, and 80 degrees C temperatures were exposed to the specimens during tensile tests. It was seen that, the load-carrying capacity of the joint is decreased gradually by increasing temperature level. In proportion to the room temperature, the maximum decrease of failure loads occurs at 70 degrees C and 80 degrees C with the rate of nearly 55% and 70% respectively, because of the heat damage to the resin matrix. Besides thermal effects, 0 and 6 Nm tightening torques were applied to observe how clamping forces affect the joint strength. The results proved that, tightening torque is effective not only at room temperature, but also at elevated temperatures and contributes to the joint strength.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEngineeringen_US
dc.subjectMaterials scienceen_US
dc.subjectGlass fibersen_US
dc.subjectHigh-temperature propertiesen_US
dc.subjectMechanical testingen_US
dc.subjectJoints/joiningen_US
dc.subjectBearing strengthen_US
dc.subjectBehavioren_US
dc.subjectGlass fibersen_US
dc.subjectTensile testingen_US
dc.subjectClamping forceen_US
dc.subjectFailure analysisen_US
dc.subjectComposite jointen_US
dc.subjectE. Joints/Joiningen_US
dc.subjectElevated temperatureen_US
dc.subjectFailure behaviorsen_US
dc.subjectFailure loaden_US
dc.subjectHeat damageen_US
dc.subjectJoint strengthen_US
dc.subjectResin matrixen_US
dc.subjectRoom temperatureen_US
dc.subjectSingle lapsen_US
dc.subjectTemperature levelen_US
dc.subjectTensile testsen_US
dc.subjectThermal conditionen_US
dc.subjectTightening torqueen_US
dc.titleFailure analysis of mechanically fastened glass fiber/epoxy composite joints under thermal effectsen_US
dc.typeArticleen_US
dc.identifier.wos000314193200022tr_TR
dc.identifier.scopus2-s2.0-84869497474tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.contributor.departmentUludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.tr_TR
dc.identifier.startpage192tr_TR
dc.identifier.endpage199tr_TR
dc.identifier.volume45tr_TR
dc.identifier.issue1tr_TR
dc.relation.journalComposites Part B- Engineeringen_US
dc.contributor.buuauthorKorkmaz, Behiye-
dc.relation.collaborationYurt içitr_TR
dc.subject.wosEngineering, multidisciplinaryen_US
dc.subject.wosMaterials science, compositesen_US
dc.indexed.wosSCIEen_US
dc.indexed.scopusScopusen_US
dc.wos.quartileQ1en_US
dc.contributor.scopusid6603043481tr_TR
dc.subject.scopusBolted Joints; Bolts; Damageen_US
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.


DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.