Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/29859
Title: Performance optimization of absorption refrigeration systems using Taguchi, ANOVA and grey relational analysis methods
Authors: Bademli̇oğlu, Ali Hüsnü
Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.
0000-0003-4970-4490
Canbolat, Ahmet Serhan
Arslanoǧlu, Nurullah
Kaynaklı, Ömer
57196950859
54956660200
8387145900
Keywords: Absorption refrigeration system
Taguchi method
Grey relational analysis
Anova
Cop
eCop
Flat-plate collector
Heat-exchanger
Thermodynamic analysis
Exergy analyses
Parameters
Energy
Desing
Cycle
Air
Analysis of variance (anova)
Efficiency
Evaporators
Heat exchangers
Refrigerants
Taguchi methods
Absorption refrigeration system
Grey relational analysis
Optimum operating conditions
Performance characteristics
Performance optimizations
Taguchi grey relational analysis
Thermodynamic performance
Absorption refrigeration
Science & technology - other topics
Engineering
Environmental sciences & ecology
Issue Date: 20-May-2019
Publisher: Elsevier Science
Citation: Canbolat, A. S. vd. (2019). ''Performance optimization of absorption refrigeration systems using Taguchi, ANOVA and grey relational analysis methods''. Journal of Cleaner Production, 229, 874-885.
Abstract: There are various factors having an impact on the energetic and exergetic performance (i.e., COP and eCOP) of an absorption refrigeration systems (ARS) such as the temperatures of the generator, condenser, evaporator and absorber, effectiveness of solution, refrigerant and solution-refrigerant heat exchangers and isentropic efficiency of the solution pump. Many studies have focused on these process parameters, but the importance order and contribution ratios of the parameters due to thermodynamic performance have not been determined by using statistical methods. Firstly, in this study, cycles' thermodynamic model is established and the variation of the COP and eCOP are calculated for different working conditions with different parameters ranges. The effects of these parameters on the COP and eCOP are examined separately on a statistical basis. The importance order of the parameters are determined by using Taguchi and ANOVA methods and the results are compared. Optimum operating conditions are determined by means of statistical analysis for the COP and eCOP. Under these operating conditions, the COP and eCOP of the system are calculated as 0.697 and 0.2829, respectively. Furthermore, for the simultaneous maximization of these two performance indicators, Taguchi-Grey Relational Analysis (GRA) is used. By using this analysis, importance order of the examined parameters on multiple performance characteristics are determined. The absorber and evaporator temperatures are the most efficient parameters on multiple performance characteristics with a contribution ratio of 29.66% and 26.34% of the total effect while the least efficient parameters are the pump efficiency and effectiveness of solution refrigerant heat exchanger with a contribution ratio of 0.48% and 2.41%, respectively. For the best condition considering the multiple performance characteristics, COP and eCOP of the system are found as 0.6255 and 0.2829, respectively.
URI: https://doi.org/10.1016/j.jclepro.2019.05.020
https://www.sciencedirect.com/science/article/pii/S0959652619315367
http://hdl.handle.net/11452/29859
ISSN: 0959-6526
1879-1786
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.