Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/30179
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Şahin, Namık | - |
dc.contributor.author | Kurtoǧlu, Ünal | - |
dc.contributor.author | Turgut, Ali | - |
dc.contributor.author | Özkan, Yüksel | - |
dc.date.accessioned | 2022-12-30T07:59:52Z | - |
dc.date.available | 2022-12-30T07:59:52Z | - |
dc.date.issued | 2012-07-19 | - |
dc.identifier.citation | Şahin, N. vd. (2013). "Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement". Knee Surgery Sports Traumatology Arthroscopy, 21(10), 2384-2391. | en_US |
dc.identifier.issn | 0942-2056 | - |
dc.identifier.issn | 1433-7347 | - |
dc.identifier.uri | https://doi.org/10.1007/s00167-012-2120-5 | - |
dc.identifier.uri | https://link.springer.com/article/10.1007/s00167-012-2120-5 | - |
dc.identifier.uri | http://hdl.handle.net/11452/30179 | - |
dc.description.abstract | The purpose of the present study was to determine whether the axes aligned with the sulcus between the tibial spines and the middle of the posterior cruciate ligament at the knee and with the tibialis anterior tendon at the ankle provide a neutral rotational and coronal alignment of the tibial component in total knee arthroplasty (TKA). In a cohort of 45 TKA patients, CT scans were taken to quantify coronal and rotational positioning of the components. All patients received a posterior stabilised total knee replacement with a fixed insert (PFC Sigma; DePuy Orthopaedics, Inc; Warsaw, IN, USA). The tibial guide was aligned with the sulcus between the tibial spines and the middle of the posterior cruciate ligament at the knee and with the tibialis anterior tendon at the ankle. The average post-operative coronal mechanical alignment was 1A degrees varus (range 4.5A degrees varus-1.5A degrees valgus; SD +/- 1.51). The average post-operative rotational deviation from the transepicondylar axes (TEA) was 0.78A degrees of internal rotation (1.50A degrees of internal rotation - 3.5A degrees of external rotation) for the tibial component. The whole-extremity mechanical axis deviation was outside the tolerance range of 3A degrees in 4 patients (8.9 %). Deviation of the tibial component rotational position relative to the TEA was 3A degrees or less in 94.5 % of the patients. When the tibial component is aligned using the axis drawn from the centre of the PCL to the sulcus between the tibial spines on the proximal tibia and to the tibialis anterior tendon at the ankle, good alignment will be achieved in both the coronal and axial planes. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Orthopedics | en_US |
dc.subject | Sport sciences | en_US |
dc.subject | Surgery | en_US |
dc.subject | Knee | en_US |
dc.subject | Osteoarthritis | en_US |
dc.subject | Total knee arthroplasty | en_US |
dc.subject | Coronal alignment | en_US |
dc.subject | Rotational alignment | en_US |
dc.subject | Tibial component | en_US |
dc.subject | Total knee arthroplasty | en_US |
dc.subject | Computer-assisted navigation | en_US |
dc.subject | Rotational alignment | en_US |
dc.subject | Transepicondylar axis | en_US |
dc.subject | Femoral component | en_US |
dc.subject | Reproducibility | en_US |
dc.subject | Variability | en_US |
dc.subject | Replacement | en_US |
dc.subject | References | en_US |
dc.subject | Position | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Anatomic landmarks | en_US |
dc.subject.mesh | Ankle joint | en_US |
dc.subject.mesh | Arthroplasty, replacement, knee | en_US |
dc.subject.mesh | Bone malalignment | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Follow-up studies | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Knee joint | en_US |
dc.subject.mesh | Knee prosthesis | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle aged | en_US |
dc.subject.mesh | Osteoarthritis, knee | en_US |
dc.subject.mesh | Posterior cruciate ligament | en_US |
dc.subject.mesh | Postoperative complications | en_US |
dc.subject.mesh | Prospective studies | en_US |
dc.subject.mesh | Rotation | en_US |
dc.subject.mesh | Tendons | en_US |
dc.subject.mesh | Tibia | en_US |
dc.subject.mesh | Tomography x-ray computed | en_US |
dc.subject.mesh | Treatment outcome | en_US |
dc.title | Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000324641800028 | tr_TR |
dc.identifier.scopus | 2-s2.0-84884533417 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Ortopedi ve Travmatoloji Anabilim Dalı. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Biyoistatistik Anabilim Dalı. | tr_TR |
dc.contributor.orcid | 0000-0003-0297-846X | tr_TR |
dc.identifier.startpage | 2384 | tr_TR |
dc.identifier.endpage | 2391 | tr_TR |
dc.identifier.volume | 21 | tr_TR |
dc.identifier.issue | 10 | tr_TR |
dc.relation.journal | Knee Surgery Sports Traumatology Arthroscopy | en_US |
dc.contributor.buuauthor | Atıcı, Teoman | - |
dc.contributor.buuauthor | Özkaya, Güven | - |
dc.contributor.researcherid | A-5095-2018 | tr_TR |
dc.contributor.researcherid | A-4421-2016 | tr_TR |
dc.relation.collaboration | Sanayi | tr_TR |
dc.identifier.pubmed | 22751944 | tr_TR |
dc.subject.wos | Orthopedics | en_US |
dc.subject.wos | Sport sciences | en_US |
dc.subject.wos | Surgery | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.pubmed | PubMed | en_US |
dc.wos.quartile | Q1 | en_US |
dc.contributor.scopusid | 7801647288 | tr_TR |
dc.contributor.scopusid | 16316866500 | tr_TR |
dc.subject.scopus | Biomechanics; Thighs; Collateral Ligaments | en_US |
dc.subject.emtree | Aged | en_US |
dc.subject.emtree | Anatomic landmark | en_US |
dc.subject.emtree | Ankle | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Bone malformation | en_US |
dc.subject.emtree | Clinical article | en_US |
dc.subject.emtree | Computer assisted tomography | en_US |
dc.subject.emtree | Equipment | en_US |
dc.subject.emtree | Female | en_US |
dc.subject.emtree | Follow up | en_US |
dc.subject.emtree | Histology | en_US |
dc.subject.emtree | Human | en_US |
dc.subject.emtree | Knee | en_US |
dc.subject.emtree | Knee arthroplasty | en_US |
dc.subject.emtree | Knee ligament | en_US |
dc.subject.emtree | Knee osteoarthritis | en_US |
dc.subject.emtree | Knee prosthesis | en_US |
dc.subject.emtree | Male | en_US |
dc.subject.emtree | Methodology | en_US |
dc.subject.emtree | Middle aged | en_US |
dc.subject.emtree | Postoperative complication | en_US |
dc.subject.emtree | Prospective study | en_US |
dc.subject.emtree | Radiography | en_US |
dc.subject.emtree | Rotation | en_US |
dc.subject.emtree | Tendon | en_US |
dc.subject.emtree | Tibia | en_US |
dc.subject.emtree | Treatment outcome | en_US |
Appears in Collections: | PubMed Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.