Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/30863
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Akkurt, İskender | - |
dc.date.accessioned | 2023-02-07T06:54:18Z | - |
dc.date.available | 2023-02-07T06:54:18Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Kuluöztürk, Z. N. vd. (2017). ''Monte Carlo simulation studies of collimator parameters for TARLA bremsstrahlung facility''. Acta Physica Polonica A, 132(3), 796-800. | en_US |
dc.identifier.issn | 0587-4246 | - |
dc.identifier.uri | https://doi.org/10.12693/APhysPolA.132.796 | - |
dc.identifier.uri | 1898-794X | - |
dc.identifier.uri | http://przyrbwn.icm.edu.pl/APP/PDF/132/app132z3p106.pdf | - |
dc.identifier.uri | http://hdl.handle.net/11452/30863 | - |
dc.description | Bu çalışma, 19-24 Ekim 2016 tarihleri arasında Antalya[Türkiye]’da düzenlenen 3. International Conference on Computational and Experimental Science and Engineering (ICCESEN)’da bildiri olarak sunulmuştur. | tr_TR |
dc.description.abstract | In this work, calculations of the design of bremsstrahlung photon collimator within the scope of the Turkish Accelerator Center Project are presented. At TARLA facility (Turkish Accelerator Radiation Laboratory at Ankara), bremsstrahlung photons created by the accelerated electron beams, are transferred to the experimental area through the collimator, which has a conical geometry with length of 320 cm. In this study, Al, Fe and Cu materials were selected as collimator materials. All interactions between the collimator materials and Gaussian photon beam in 8-32 MeV energy range (8 MeV, 16 MeV, 24 MeV and 32 MeV) were taken into account. The entry radius, geometry and chosen materials are important parameters for collimator design. The photon fluence from collimator, secondary particle distributions and the number of photons, scattered from the collimator, were calculated as functions of these parameters. All calculations were made with the Monte Carlo code FLUKA. According to the results of these simulations, collimator with conical geometry, made of aluminium, with 0.25 cm entry radius, was determined to be appropriate for TARLA bremsstarhlung photon facility of Turkish Accelerator Center. | en_US |
dc.description.sponsorship | Türkiye Devlet Planlama Teşkilatı DPT2006K-120470 | tr_TR |
dc.description.sponsorship | Süleyman Demirel Üniversitesi 3407-D2-12 | tr_TR |
dc.language.iso | en | en_US |
dc.publisher | Polish Acad Sciences Inst Physics | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Atıf Gayri Ticari Türetilemez 4.0 Uluslararası | tr_TR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Physics | en_US |
dc.subject | Photon-scattering | en_US |
dc.subject | Gaussian beams | en_US |
dc.subject | Geometry | en_US |
dc.subject | Intelligent systems | en_US |
dc.subject | Photons | en_US |
dc.subject | Accelerated electron beam | en_US |
dc.subject | Conical geometry | en_US |
dc.subject | Monte Carlo codes | en_US |
dc.subject | Photon beams | en_US |
dc.subject | Photon collimators | en_US |
dc.subject | Photon fluence | en_US |
dc.subject | Radiation laboratory | en_US |
dc.subject | Secondary particles | en_US |
dc.subject | Monte Carlo methods | en_US |
dc.title | Monte Carlo simulation studies of collimator parameters for TARLA bremsstrahlung facility | en_US |
dc.type | Article | en_US |
dc.type | Proceedings Paper | en_US |
dc.identifier.wos | 000412881200107 | tr_TR |
dc.identifier.scopus | 2-s2.0-85033387777 | tr_TR |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü. | tr_TR |
dc.contributor.orcid | 0000-0003-2245-8461 | tr_TR |
dc.identifier.startpage | 796 | tr_TR |
dc.identifier.endpage | 800 | tr_TR |
dc.identifier.volume | 132 | tr_TR |
dc.identifier.issue | 3 | tr_TR |
dc.relation.journal | Acta Physica Polonica A. | en_US |
dc.contributor.buuauthor | Demir, N. | - |
dc.contributor.researcherid | AAH-3156-2021 | tr_TR |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.subject.wos | Physics, multidisciplinary | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.wos | CPCIS | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q3 | en_US |
dc.contributor.scopusid | 7006874016 | tr_TR |
dc.subject.scopus | Photoneutrons; Transition Density; Nucleus | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Demir_vd_2017.pdf | 776.05 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License