Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/32172
Title: | Assessment of Liliequist membrane by 3D-SPACE technique at 3 T |
Authors: | Algın, Oktay Kilin, Mehmet Özmen, Evrim Uludağ Üniversitesi/Tıp Fakültesi/Biyoistatistik Anabilim Dalı. Ocakoğlu, Gökhan HLG-6346-2023 AAH-5180-2021 15832295800 |
Keywords: | Neurosciences & neurology Radiology, nuclear medicine & medical imaging MRI Liliequist's membrane CSF Third ventriculostomy 3D-SPACE 3-dimensional constructive interference Endoscopic 3rd ventriculostomy Flip-angle evolutions Sampling perfection Subarachnoid cisterns Sequence Stenosis |
Issue Date: | 25-Feb-2016 |
Publisher: | Springer |
Citation: | Algın, O. vd. (2016). "Assessment of Liliequist membrane by 3D-SPACE technique at 3 T". Neuroradiology, 58(7), 637-647. |
Abstract: | Liliequist membrane (LM) is the most important anatomic structure for the success of endoscopic third ventriculostomy (ETV). Identification of this membrane is difficult with conventional MRI techniques. The purpose of this retrospective study is to determine the impact of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence with variant flip-angle mode (VFAM) in the assessment of LM at 3-T MRI devices. 3D-SPACE with VFAM images were obtained in 445 patients. LM visibility and integrity were scored as 0 (good), 1 (moderate), and 2 (poor) on these images for each parts (sellar, diencephalic, and mesencephalic) and overall of the membrane. According to the LM overall integrity scores, 11 % (48 cases) of the patients had perforated membrane. According to subsegmental integrity scores, sellar part was completely intact in 63 % of patients, diencephalic segment was completely intact in 60 % of the patients, and mesencephalic segment was completely intact in 95 % of the patients. Visibility scores of the third ventricle inferior wall were significantly higher in the patients with intact LM (p = 0.001). There was not any statistically significant relationship between LM pattern and overall integrity (p = 0.352). LM attachment sites could be detected easier in the patients who had better visibility of third ventricle inferior wall or intact LM (p < 0.001 for both). 3D-SPACE technique is a useful alternative for the evaluation of morphology, integrity, individual variations, topographic relationships, and visibility of LM since it has some advantages including lower SAR values, fewer artifacts, and high-resolution images. |
URI: | https://doi.org/10.1007/s00234-016-1669-y https://link.springer.com/article/10.1007/s00234-016-1669-y http://hdl.handle.net/11452/32172 |
ISSN: | 0028-3940 1432-1920 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.