Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/32782
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Meydan, Turgut | - |
dc.date.accessioned | 2023-05-25T10:39:25Z | - |
dc.date.available | 2023-05-25T10:39:25Z | - |
dc.date.issued | 2013-01 | - |
dc.identifier.citation | Taysioğlu, A. A . vd. (2013). “The influence of the magnetic susceptibility of coated amorphous ribbons on giant-magneto impedance effect”. Sensor Letters, 11(1), Special Issue, 81-83. | en_US |
dc.identifier.issn | 1546-198X | - |
dc.identifier.issn | 1546-1971 | - |
dc.identifier.uri | https://doi.org/10.1166/sl.2013.2815 | - |
dc.identifier.uri | https://www.ingentaconnect.com/content/asp/senlet/2013/00000011/00000001/art00020;jsessionid=15q0pqg4887sj.x-ic-live-03 | - |
dc.identifier.uri | http://hdl.handle.net/11452/32782 | - |
dc.description.abstract | Different inorganic thin layers (based on Cobalt, Copper and Nickel complexes) were grown on the surface of Co-rich Fe5.85Co70.15Mo4B15Si5 (Metglas 2705X) amorphous ribbons by a chemical coating process to improve the giant magneto impedance (GMI) effect. Magnetic susceptibilities of the inorganic complexes were measured by the Gouy's method. Therefore, the influence of the magnetic susceptibility of thin layers, which are coated on the surfaces of the amorphous ribbons, on the GMI effect has been studied. Cobalt, copper and nickel complexes were found to be diamagnetic, paramagnetic and paramagnetic, respectively. The results showed that changes in the GMI effect are related to the magnetic susceptibility. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Amer Scientific Publishers | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Electrochemistry | en_US |
dc.subject | Instruments & instrumentation | en_US |
dc.subject | Physics | en_US |
dc.subject | Amorphous magnetic materials | en_US |
dc.subject | Giant magneto-impedance effect | en_US |
dc.subject | Atomic force microscopy | en_US |
dc.subject | Cobalt | en_US |
dc.subject | Copper | en_US |
dc.subject | Magnetic materials | en_US |
dc.subject | Magnetic susceptibility | en_US |
dc.subject | Magnetos | en_US |
dc.subject | Molybdenum | en_US |
dc.subject | Molybdenum compounds | en_US |
dc.subject | Nickel | en_US |
dc.subject | Paramagnetism | en_US |
dc.subject | Amorphous magnetic materials | en_US |
dc.subject | Amorphous ribbon | en_US |
dc.subject | Chemical coating process | en_US |
dc.subject | Giant magneto impedance effect | en_US |
dc.subject | GMI effects | en_US |
dc.subject | Inorganic complexes | en_US |
dc.subject | Nickel complex | en_US |
dc.subject | Thin layers | en_US |
dc.subject | Amorphous silicon | en_US |
dc.title | The influence of the magnetic susceptibility of coated amorphous ribbons on giant-magneto impedance effect | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000321593400019 | tr_TR |
dc.identifier.scopus | 2-s2.0-84877969737 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Anabilim Dalı. | tr_TR |
dc.relation.bap | F2009/29 | tr_TR |
dc.identifier.startpage | 81 | tr_TR |
dc.identifier.endpage | 83 | tr_TR |
dc.identifier.volume | 11 | tr_TR |
dc.identifier.issue | 1, Special Issue | en_US |
dc.relation.journal | Sensor Letters | en_US |
dc.contributor.buuauthor | Taysiogğu, Asli Ayten | - |
dc.contributor.buuauthor | Peksöz, Ahmet | - |
dc.contributor.buuauthor | Derebaşı, Naim | - |
dc.contributor.researcherid | AAI-2254-2021 | tr_TR |
dc.contributor.researcherid | AAG-9772-2021 | tr_TR |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.subject.wos | Chemistry, analytical | en_US |
dc.subject.wos | Electrochemistry | en_US |
dc.subject.wos | Instruments & instrumentation | en_US |
dc.subject.wos | Physics, applied | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.contributor.scopusid | 18038658800 | tr_TR |
dc.contributor.scopusid | 23100976500 | tr_TR |
dc.contributor.scopusid | 11540936300 | tr_TR |
dc.subject.scopus | Magnetic Sensors; Electric Impedance; Ribbons | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.