dc.identifier.citationKüçük, M. (2023). İdrarda fitalat ester metabolitlerinin tayini için moleküler baskılanmış polimer temelli katı faz ekstraksiyon metodunun geliştirilmesi. Yayınlanmamış yüksek lisans tezi. Bursa Uludağ Üniversitesi Fen Bilimleri Enstitüsü.tr_TR
dc.identifier.urihttp://hdl.handle.net/11452/33112-
dc.description.abstractBu çalışmada, idrardaki monoetil fitalat (MEP), mono-n-bütil fitalat (MnBP) ve mono- (2-etilheksil) (MEHP) fitalat monoesterlerinin gaz kromatografisi-kütle spektrometresi (GC-MS) ile tayini için moleküler baskılanmış polimer temelli bir katı faz ekstraksiyon metodu geliştirildi. Fonksiyonel monomerin metakriloil-amido-L-triptofan metil esteri (MATrp), çapraz bağlayıcının etilen glikol dimetakrilat (EGDMA), başlatıcının 2,2'- azobis(izobutironitril) (AIBN) ve dietil fitalatın (DEP) taklit (dummy) kalıp molekül olarak kullanıldığı poli[(EGDMA-MATrp)] mikroküreleri süspansiyon polimerizasyon tekniği ile sentezlendi. DEP baskılanmış poli[(EGDMA-MATrp)] mikroküreler infrared spektroskopisi (FTIR), taramalı elektron mikroskobu (SEM), Brunauer-Emmett-Teller (BET) ve X-ışını fotoelektron spektroskopisi (XPS) teknikleri ile karakterize edildi. Sentezlenen mikroküreler kullanılarak katı faz ekstraksiyon (SPE) kartuşları hazırlandı. Hazırlanan mikrokürelerin katı faz ekstraksiyon malzemesi olarak kullanılmasıyla geliştirilen metot optimize edildi. Geliştirilen yeni tayin metoduna ilişkin gözlenebilme sınırı (GS), tayin sınırı (TS), doğrusal çalışma aralığı, günler içi ve günler arası tekrarlanabilirlik gibi analitik parametreler belirlendi. İlgili fitalat monoesterler için GS ve TS değerleri sırasıyla 0,04-1,20 µg/L ve 0,15-4,01 µg/L aralığında bulundu. Korelasyon katsayısı kareleri değerleri 0,9778-0,9993 aralığında, yüzde bağıl standart sapma (%BSS) verileri gün içi çalışmalar için 1,10-2,29 ve günler arası çalışmalar için 4,49-9,34 aralığında bulundu. Optimize edilen SPE koşullarında, yeni hazırlanan SPE kartuşu ticari OASIS HLB kartuşuyla karşılaştırıldı. Son olarak, insan idrar örnekleriyle çalışılarak metodun gerçek örneklere uygulanabilirliği belirlendi. Sonuç olarak fitalat monoesterlerin (MEP, MnBP ve MEHP) tayin için yeni bir SPE metodu geliştirildi.tr_TR
dc.description.abstractIn this study, a molecularly imprinted polymer-based solid phase extraction method was developed for the determination of monoethyl phthalate (MEP), mono-n-butyl phthalate (MnBP) and mono-(2-ethylhexyl) (MEHP) phthalate monoesters in urine by gas chromatography-mass spectrometry (GC-MS). Methacryloyl-amido-L-tryptophan methyl ester of functional monomer (MATrp), crosslinker ethylene glycol dimethacrylate (EGDMA), initiator 2,2'-azobis(isobutyronitrile) (AIBN) and diethyl phthalate (DEP) as dummy template molecule poly[(EGDMA-MATrp)] microspheres were synthesized by suspension polymerization technique. DEP-imprinted poly[(EGDMA-MATrp)] microspheres were characterized by infrared spectroscopy (FTIR), scanning electron microscopy (SEM), Brunauer-Emmett-Teller (BET) and X-ray photoelectron spectroscopy (XPS) techniques. Solid phase extraction (SPE) cartridges were prepared using synthesized microspheres. The developed method was optimized by using the prepared microspheres as solid phase extraction material. Analytical parameters such as limit of detection (LOD), limit of quantification (LOQ), linear range, intra-day and inter-day repeatability were determined for the new detection method developed. LOD and LOQ values were found in the range of 0,04-1,20 µg/L and 0,15-4,01 µg/L for respective phthalate monoesters, respectively. The squares of the correlation coefficient were in the range of 0.9778-0.9993, the relative standard deviation (%RSD) values were found in the range of 1.10-2.29 for intra-day and 4.49- 9.34 for inter-day studies. Under optimized SPE conditions, the novel prepared SPE cartridge was compared to the commercial OASIS HLB cartridge. Finally, the applicability of the method to real samples was determined by working with human urine samples. As a result, a new SPE method was developed for determination of phthalate monoesters.en_US
dc.format.extentXV, 113 sayfatr_TR
dc.language.isotrtr_TR
dc.publisherBursa Uludağ Üniversitesitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAtıf 4.0 Uluslararasıtr_TR
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectFitalat monoesteritr_TR
dc.subjectMoleküler baskılamatr_TR
dc.subjectKatı faz ekstraksiyontr_TR
dc.subjectGaz kromatografisitr_TR
dc.subjectPhthalate monoesteren_US
dc.subjectMolecular imprintingen_US
dc.subjectSolid phase extractionen_US
dc.subjectGas chromatographyen_US
dc.titleİdrarda fitalat ester metabolitlerinin tayini için moleküler baskılanmış polimer temelli katı faz ekstraksiyon metodunun geliştirilmesitr_TR
dc.title.alternativeDevelopment of molecularly imprinted polymer-based solid phase extraction method for the determination of phthalate ester metabolites in urineen_US
dc.typemasterThesisen_US
dc.relation.publicationcategoryTeztr_TR
dc.contributor.departmentBursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Kimya Anabilim Dalı.tr_TR
dc.relation.bapFGA-2021-635tr_TR
dc.contributor.orcid0009-0003-3550-5682tr_TR
Appears in Collections:Fen Bilimleri Yüksek Lisans Tezleri / Master Degree

Files in This Item:
File Description SizeFormat 
Melike_Küçük.pdf3.47 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons