Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/33481
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGündoğdu, Özcan-
dc.date.accessioned2023-08-11T13:29:51Z-
dc.date.available2023-08-11T13:29:51Z-
dc.date.issued2017-09-
dc.identifier.citationGündoğdu, Ö. vd. (2017). ''Monte Carlo calculations for photon attenuation studies on different solid phantom materials''. Acta Physica Polonica A, 132(3), Special Issue, Part 2,1032-1035.en_US
dc.identifier.issn0587-4246-
dc.identifier.issn1898-794X-
dc.identifier.urihttps://doi.org/10.12693/APhysPolA.132.1032-
dc.identifier.urihttp://przyrbwn.icm.edu.pl/APP/PDF/132/app132z3-IIp060.pdf-
dc.identifier.urihttp://hdl.handle.net/11452/33481-
dc.descriptionBu çalişma, 19-24, Ekim 2016 tarihlerinde Antalya[Türkiye]’de düzenlenen 3.International Conference on Computational and Experimental Science and Engineering (ICCESEN) Kongresi‘nde bildiri olarak sunulmuştur.tr_TR
dc.description.abstractThe linear attenuation coefficients of water and some solid phantom materials, namely of solid water RMI-457, of plastic water, of RW3 solid water, and of Perspex were determined by Monte Carlo calculations, for gamma-ray photons with energies of 59.5, 80.9, 140.5, 356.5, 661.6, 1173.2, and 1332.5 keV. The calculated values were compared with the experimental results presented by other researchers and with theoretical values obtained using the XCOM database. Good agreement was observed between the calculations, the experimental, and the theoretical values. The results indicate that the process in Monte Carlo code can be followed to determine the equivalency of other materials at several energies. Three shielding factors such as half-value layer, tenth-value layer, and mean free path were calculated at all considered gamma-ray energies.en_US
dc.language.isoentr_TR
dc.publisherPolish Acad Sciences Inst Physicsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAtıf Gayri Ticari Türetilemez 4.0 Uluslararasıtr_TR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectPhysicsen_US
dc.subjectGamma-ray transmissionen_US
dc.subjectCoefficientsen_US
dc.subjectGlassesen_US
dc.subjectMonte carlo methodsen_US
dc.subjectPhotonsen_US
dc.subjectCalculated valuesen_US
dc.subjectGamma-ray energyen_US
dc.subjectGamma-ray photonsen_US
dc.subjectLinear attenuation coefficientsen_US
dc.subjectMonte carlo calculationen_US
dc.subjectMonte Carlo codecen_US
dc.subjectPhoton attenuationen_US
dc.subjectTheoretical valuesen_US
dc.subjectGamma raysen_US
dc.titleMonte Carlo calculations for photon attenuation studies on different solid phantom materialsen_US
dc.typeArticleen_US
dc.typeProceedings Paperen_US
dc.identifier.wos000413982900060tr_TR
dc.identifier.scopus2-s2.0-85033378428tr_TR
dc.relation.publicationcategoryKonferans Öğesi - Uluslararasıtr_TR
dc.contributor.departmentUludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü.tr_TR
dc.identifier.startpage1032tr_TR
dc.identifier.endpage1035tr_TR
dc.identifier.volume132tr_TR
dc.identifier.issue3, Special Issue, Part 2en_US
dc.relation.journalActa Physica Polonica Aen_US
dc.contributor.buuauthorTarım, Urkiye Akar-
dc.contributor.buuauthorGürler, Orhan-
dc.contributor.researcheridAAH-1837-2021tr_TR
dc.contributor.researcheridAAH-4270-2021tr_TR
dc.relation.collaborationYurt içitr_TR
dc.subject.wosPhysics, multidisciplinaryen_US
dc.indexed.wosSCIEen_US
dc.indexed.wosCPCISen_US
dc.indexed.scopusScopusen_US
dc.wos.quartileQ3en_US
dc.contributor.scopusid55062460600tr_TR
dc.contributor.scopusid14019444500tr_TR
dc.subject.scopusRadiation Shield; Gamma Ray; Shieldingen_US
Appears in Collections:Scopus
Web of Science

Files in This Item:
File Description SizeFormat 
Gürler_vd_2017.pdf388.73 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons