Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/34330
Title: | Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: An in-vitro study |
Authors: | Bayrak, Seval Orhan, Kaan Cakmak, Emine Sebnem Kursun Odabaşı, Onur Yılmaz, Derviş Atakan, Cemal Uludağ Üniversitesi/Diş Hekimliği Fakültesi/Klinik Bilimler Bölümü. 0000-0002-3083-1660 Görürgöz, Cansu AAQ-4576-2020 57203843503 |
Keywords: | Dentistry, oral surgery & medicine Root fractures Zirconium Systems Sizes CBCT CT |
Issue Date: | Aug-2020 |
Publisher: | Elsevier |
Citation: | Bayrak, S. vd. (2020). "Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study". Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 130(2), 209-216 |
Abstract: | Objectives: The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Study Design: Nine implants (3 zirconium, 3 titanium, and 3 zirconium-titanium) were placed in 3 sheep heads. Dehiscences were created on the buccal and lingual/palatal surfaces. A total of 9 defects and 9 controls with no defects were evaluated by 3 observers. Each sheep head was scanned 5 times with 4 scan modes; (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO. Receiver operating characteristic analysis and weighted kappa coefficients were used to calculate diagnostic efficacy and intra- and interobserver agreements for each implant type and scan mode. Results: For all implant types, dehiscences were most accurately detected when both MAR and AINO were applied (P ≤.045). Detection of dehiscences was more accurate with titanium implants (P ≤.040). There were no significant differences in agreement among and between the observers. Conclusions: The use of both MAR and AINO enhanced the detection accuracy of artificially created dehiscences in proximity to implants. Their combined use is recommended for detecting peri-implant dehiscences. |
URI: | https://doi.org/10.1016/j.oooo.2020.02.005 https://www.sciencedirect.com/science/article/pii/S2212440320300390 http://hdl.handle.net/11452/34330 |
ISSN: | 22124403 2212-4411 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.