dc.contributor.authorMerev, Ahmet-
dc.date.accessioned2020-09-02T10:54:24Z-
dc.date.available2020-09-02T10:54:24Z-
dc.date.issued2018-09-06-
dc.identifier.citationMerev, A. (2018). "Geniş bant gerilim referanslı bir yüksek gerilim bölücüsünün uzun dönem gerilim kararlılığının belirlenmesi". Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, 23(3), 1-10.tr_TR
dc.identifier.issn2148-4147-
dc.identifier.issn2148-4155-
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/559928-
dc.identifier.urihttp://hdl.handle.net/11452/12505-
dc.description.abstract2012 yılında yapımı gerçekleştirilen referans yüksek doğru gerilim bölücüsü, dirençsel elemanlardan oluşan geleneksel tipte bir gerilim bölücüsü olmayıp yapısında şönt tipi gerilim referansları bulunmaktadır. UME-20 adı verilen gerilim bölücüsünün, belirsizlik hesaplamalarında gerilim referanslarının oluşturduğu modüllerin sıcaklık katsayısı, ölçüm sisteminin akım bağlılığı, kaçak akım ve korona etkisi, sıcaklığa bağlılığının neden olduğu kısa dönem kararlılığı ve doğru gerilim ölçme belirsizlik bileşenleri göz önünde bulundurulmuştur. Çalışma tamamlandığında belirsizlik hesapları yapılırken gerilim bölücüsünün uzun dönem sapma değerlerine ait veriler bulunmadığından, bu bileşen kullanılmamış ve ölçüm belirsizliği 5 µV/V olarak hesaplanmıştır. IEC 60060-2 standardına göre ölçüm sistemlerinin uzun dönem kararlığı, ölçme belirsizliğine doğrudan etki etmektedir. Bu nedenle referans ölçüm sisteminin sapması 2012-2017 yılları arasındaki dönemde incelenmiş ve belirsizlik hesaplamalarına bu etkinin katılmasını sağlanmıştır. Bu sapma değeri, toplam belirsizlik hesaplamalarına katılmış ve ölçme sisteminin belirsizlik hesaplarında düzeltme yapılmıştır. Bu çalışmada, yapısında şönt tipi gerilim referansı bulunan 20 kV referans yüksek doğru gerilim ölçüm sisteminin uzun dönem kararlılığı incelenmiş ve belirsizlik hesapları bu etki göz önünde bulundurularak yeniden yapılmıştır.tr_TR
dc.description.abstractThe reference HVDC voltage divider constructed in 2012 is not a conventional voltage divider made up of resistive elements but has shunt type voltage references in its structure. The components in the uncertainty calculations are based on the temperature coefficient of the voltage reference, the current dependence of the measurement system, the leakage current and the corona effect, the short term stability caused by the thermal dependence and the DC voltage measurement uncertainty components. The uncertainty calculation has been done without long term stability effect since there is no data for the longterm deviation of the voltage divider. The measurement uncertainty was calculated to be 5 μV/V without considering this effect. According to the IEC 60060-2, the long-term stability of measurement systems has a direct impact on the measurement uncertainty. For this reason, the deviation of the reference measurement system is examined in the period between 2012 and 2017 and it is ensured that the uncertainty calculations include this effect. In this study, the long-term stability of a 20 kV reference DC high voltage measurement system based on the shunt type voltage references in its structure was analyzed and uncertainty were recalculated considering this effect.en_US
dc.language.isotrtr_TR
dc.publisherUludağ Üniversitesitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAtıf 4.0 Uluslararasıtr_TR
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectYüksek doğru gerilim bölücüsütr_TR
dc.subjectYüksek gerilim ölçmetr_TR
dc.subjectÖlçüm belirsizliğitr_TR
dc.subjectMetrolojitr_TR
dc.subjectKalibrasyontr_TR
dc.subjectHVDC voltage divideren_US
dc.subjectHigh voltage measurementen_US
dc.subjectMeasurement uncertaintyen_US
dc.subjectMetrologyen_US
dc.subjectCalibrationen_US
dc.titleGeniş bant gerilim referanslı bir yüksek gerilim bölücüsünün uzun dönem gerilim kararlılığının belirlenmesitr_TR
dc.title.alternativeDetermination of long-term voltage stability of high voltage divider having bandgap voltage referencesen_US
dc.typeArticleen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.identifier.startpage1tr_TR
dc.identifier.endpage10tr_TR
dc.identifier.volume23tr_TR
dc.identifier.issue3tr_TR
dc.relation.journalUludağ Üniversitesi Mühendislik Dergisi / Uludağ University Journal of The Faculty of Engineeringtr_TR