Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/21029
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.date.accessioned | 2021-07-05T06:04:50Z | - |
dc.date.available | 2021-07-05T06:04:50Z | - |
dc.date.issued | 1998 | - |
dc.identifier.citation | Bekar, A. vd. (1998). "Complications of brain tissue pressure monitoring with a fiberoptic device". Neurosurgical Review, 21(4), 254-259. | en_US |
dc.identifier.issn | 0344-5607 | - |
dc.identifier.uri | https://doi.org/10.1007/BF01105781 | - |
dc.identifier.uri | https://link.springer.com/article/10.1007/BF01105781 | - |
dc.identifier.uri | http://hdl.handle.net/11452/21029 | - |
dc.description.abstract | Seventy-five patients with intracranial hypertension whose Glasgow Coma Score (GCS) was 8 or below and in whom intracranial pressure (ICP) was monitored were examined for complications of this procedure. In 20 of the 75 patients we used only an intraparenchymal fiberoptic ICP monitoring transducer, while, in the remaining 55 patients, who required CSF drainage, a ventricular drainage set (VDS) was used in addition to ICP monitoring. The duration of monitoring with the ICP transducer alone was approximately 5.1 +/- 2.6 das (min. 1, max. 13) and that of ICP monitoring with VDS was 6.2 +/- 3.1 days (min. 1, max. 13). In 8 cases a total of 9 complications were experienced (12 %). These complications were infection in 3 cases (4 %), epidural hematoma in 2 cases (2.7 %): disconnection in 2 cases (2.7 %) and contusion in 2 cases (2.7 %). Although none of the 44 patients who were monitored for less than 5 days experienced infection, 3 of the 31 patients monitored for longer than 5 days did experience infection (9.7 %) (p < 0.05). None of the 20 patients who underwent ICP monitoring only experienced infection. However, 3 of the 55 patients in whom the ventricular drainage set was implanted in addition to the transducer for ICP monitoring experienced infection (p < 0.05). Owing to its minimally invasive nature, low complication rate, and accuracy in monitoring the parenchyma pressure, the Camino fiberoptic intraparenchymal monitor has become the system of choice in our clinic. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Neurosciences & neurology | en_US |
dc.subject | Surgery | en_US |
dc.subject | Complications | en_US |
dc.subject | Fiberoptic device | en_US |
dc.subject | Intracranial pressure monitoring | en_US |
dc.subject | Severe head-injury | en_US |
dc.subject | Intracranial-pressure | en_US |
dc.subject | Aggressive treatment | en_US |
dc.subject | Clinical-evaluation | en_US |
dc.subject | Ventriculostomy | en_US |
dc.subject | Infections | en_US |
dc.subject | Management | en_US |
dc.subject | Risk | en_US |
dc.title | Complications of brain tissue pressure monitoring with a fiberoptic device | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000078715800007 | tr_TR |
dc.identifier.scopus | 2-s2.0-0032451796 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Nöroşirurji Anabilim Dalı. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Anesteziyoloji ve Reanimasyon Anabilim Dalı. | tr_TR |
dc.contributor.orcid | 0000-0002-1190-6831 | tr_TR |
dc.identifier.startpage | 254 | tr_TR |
dc.identifier.endpage | 259 | tr_TR |
dc.identifier.volume | 21 | tr_TR |
dc.identifier.issue | 4 | tr_TR |
dc.relation.journal | Neurosurgical Review | en_US |
dc.contributor.buuauthor | Bekar, Ahmet | - |
dc.contributor.buuauthor | Gören, Suna | - |
dc.contributor.buuauthor | Korfalı, Ender | - |
dc.contributor.buuauthor | Aksoy, Kaya | - |
dc.contributor.buuauthor | Boyacı, Suat | - |
dc.contributor.researcherid | AAI-3551-2021 | tr_TR |
dc.identifier.pubmed | 10068186 | tr_TR |
dc.subject.wos | Clinical neurology | en_US |
dc.subject.wos | Surgery | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.pubmed | Pubmed | en_US |
dc.wos.quartile | Q4 | en_US |
Appears in Collections: | Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.