Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/21040
Title: Determination of theophylline and ephedrine HCL in tablets by ratio-spectra derivative spectrophotometry and LC
Authors: Şentürk, Zühre
Erk, Nevin
Özkan, Sibel A.
Akay, Cemal
Cevheroğlu, Şemsettin
Keywords: High-performance liquid chromatography
Theophylline and ephedrine hydrochloride determination
Ratio-spectra derivative spectrophotometry
Pharmaceutical formulation
Trimethoprim
Performance liquid-chromatography
Pharmaceutical formulations
Chlorpheniramine maleate
Hydrochloride
Mixtures
Hydrochlorothiazide
Resolution
Electrode
Assay
Chemistry
Pharmacology & pharmacy
Issue Date: 20-Jun-2002
Publisher: Pergamon-Elsevier Science
Citation: Şentürk, Z. vd. (2002). "Determination of theophylline and ephedrine HCL in tablets by ratio-spectra derivative spectrophotometry and LC". Journal of Pharmaceutical And Biomedical Analysis, 29(1-2), 291-298.
Abstract: Two methods are described for the determination of theophylline (THP) and ephedrine hydrochloride (EPH) in combined pharmaceutical tablet forms. The first method depends on the use of the first derivative of the ratio-spectra obtained by dividing the absorption spectrum of binary mixtures by a standard spectrum of one of the compounds. The first derivative amplitudes at 231.8 and 250.3 nm were selected for the assay of THP and EPH, respectively. Calibration graphs were established for 20-180 mug ml(-1) for THP and 10-50 mug ml(-1) for EPH. The second method is based on high-performance liquid chromatography on a reversed-phase column using a mobile phase of methanol-water (40 + 60,v/v) (pH 3) with detection at 217 nm. Linearity was obtained in the concentration range of 5-150 mug ml(-1) for THP and 15-75 mug ml(-1) for EPH. The detection limits for THP and EPH were 0.73 and 0.92 mug ml(-1) by ratio-spectra derivative spectrophotometry and 0.59 and 0.86 mug ml(-1) by HPLC, respectively. The proposed methods were successfully applied to the determination of these drugs in laboratory-prepared mixtures and in tablets. The relative standard deviations were found to be less than 1.5%, indicating reasonable repeatibility of both methods.
URI: https://doi.org/10.1016/S0731-7085(02)00065-1
https://www.sciencedirect.com/science/article/pii/S0731708502000651?via%3Dihub
http://hdl.handle.net/11452/21040
ISSN: 0731-7085
Appears in Collections:Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.