Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/21106
Başlık: Dry deposition fluxes and velocities of polychlorinated biphenyls (PCBs) associated with particles
Yazarlar: Odabaşı, Mustafa
Vardar, Nedim
Sofuoğlu, Aysun
Murphy, Thomas J.
Holsen, Thomas M.
Uludağ Üniversitesi/Mühendislik Fakültesi/Çevre Mühendisliği Bölümü.
Taşdemir, Yücel
AAG-9468-2021
Anahtar kelimeler: PCBs
Dry deposition
Particle deposition
Deposition velocity
Surrogate surface
Polycyclic aromatic-hydrocarbons
Dibenzo-p-dioxins
Line contamination assessment
Air partition-coefficients
Resource recovery facility
Michigan mass-balance
Atmospheric deposition
Lake-Michigan
Size distributions
Organic-compounds
Environmental sciences & ecology
Meteorology & atmospheric sciences
Yayın Tarihi: May-2004
Yayıncı: Pergamon-Elsevier Science
Atıf: Odabaşı, M. vd. (2004). “Dry deposition fluxes and velocities of polychlorinated biphenyls (PCBs) associated with particles”. Atmospheric Environment, 38(16), 2447-2456.
Özet: The interest in atmospheric deposition by the scientific community has increased a great deal over the past several years because of its significant contribution to the pollution budget of many natural waters. Dry deposition is an effective removal mechanism for polychlorinated biphenyls (PCBs) from the atmosphere. This study focuses on the understanding of the particulate dry deposition of PCBs in urban areas. In this paper, 43 chromatographic PCB congener peaks which represent 50 individual or coeluting congeners were evaluated. The PCB dry deposition fluxes were measured using a smooth, greased, knife-edge surrogate surface holding greased Mylar strips in Chicago, IL. The average PCB dry deposition flux measured (190 +/- 80 ng m(-2) day(-1)) was similar to those measured in other urban areas. Ambient air samples were also collected simultaneously with flux samples. The average apparent dry deposition velocity, calculated by dividing the fluxes to the particle phase concentrations was 5.2 +/- 2.9 cm s(-1). This value is in good agreement with the values calculated using similar techniques.
URI: https://doi.org/10.1016/j.atmosenv.2004.02.006
https://www.sciencedirect.com/science/article/pii/S1352231004001499
http://hdl.handle.net/11452/21106
ISSN: 1352-2310
Koleksiyonlarda Görünür:Web of Science

Bu öğenin dosyaları:
Dosya Açıklama BoyutBiçim 
1-s2.0-S1352231004001499-main.pdf326.1 kBAdobe PDFKüçük resim
Göster/Aç


Bu öğe kapsamında lisanslı Creative Commons License Creative Commons