Başlık: | The computer-based human thermal model |
Yazarlar: | Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü. Yiǧit, Abdulvahap 7006225124 |
Anahtar kelimeler: | Thermodynamics Mechanics Heat transfer Thermal analysis Computer simulation Data reduction Evaporation Fabrics Thermal insulation Computer-based human thermal models |
Yayın Tarihi: | 1998 |
Yayıncı: | Elsevier Science |
Atıf: | Yiğit, A. (1998). "The computer-based human thermal model". International Communications in Heat and Mass Transfer, 25(7), 969-977. |
Özet: | A computer model was developed that estimates the resistance to dry and evaporative heat transfer from fabric resistance data and rabi ic thickness data for five different clothing ensembles with the different total thermal insulation Five different clothing ensembles with the different total thermal insulation were studied. In this study, a two-dimensional computer model was developed that estimates the resistance to of the insulation on the body were simulated with 16 sedentary subjects. In this model. the human geometry is described by 16 cylindrical elements representing the head, hands.arms. thigh and etc. Thermal and evaporative resistance of each sixteen body segments are calculated. Heat generated in the body by metabolism can be lost to the environment by conduction. convection. radiation, evaporation of the moisture from skin and through respiration. The preceding relationship can be used to determine the total thermal resistance and the total evaporative resistance for each segment. Evaporative heat loss from skin is a combination of a evaporation of sweat secreted due to thermoregulatory control mechanisms and the natural dimension of water through the skin. The heat flows from body to environment through alternating clothing and air. The purpose of this paper is to develop a model for estimating total thermal insulation of clothing ensembles. Also latent and sensible heal transfer values for each body segment and whole body are found. Possible reasons for discrepancies between the observed data and predictions of the model are discussed. It seems that they are in agreement. |
URI: | https://doi.org/10.1016/S0735-1933(98)00088-8 https://www.sciencedirect.com/science/article/pii/S0735193398000888 http://hdl.handle.net/11452/21305 |
ISSN: | 0735-1933 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.