Abstract: | The power transfer capacity of an underground power cable is limited by high-temperature regions that occur along the cable. It is very difficult to determine and control these 'hot spots'. Optimum use and temperature profile control of power cables before and during load transmission can be achieved with real-time processing of temperature data. There are various methods developed for this purpose such as conventional point temperature measurement method, where a large number of sensors and connectors are required, and methods based on mathematical models which can only approach real values by approximation. In this study, temperature detection in an XLPE insulated 154 kV power cable is performed using a distributed sensing method where the optical fiber itself behaves as a sensor. Therefore, there is no need for the devices of conventional method. Moreover, contrary to methods based on mathematical models, where it is difficult to predict environmental variations, this method considers the variations with a temperature resolution of +/- 1 degrees C. Distributed temperature sensing (DTS) method, detection system configuration and required system parameters are explained in the paper. Experimental results obtained for 126 and 412m cables show a temperature resolution of 1 degrees C and a spatial resolution of 1.22 m. Simulations for a 10 kin cable are also given. Results show that DTS is a reliable method for both short and long range cable systems. |
URI: | https://doi.org/10.1016/j.sna.2005.06.024 https://www.sciencedirect.com/science/article/pii/S0924424705003766 http://hdl.handle.net/11452/21464 |
ISSN: | 0924-4247 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.