Başlık: | Effect of successful coronary angioplasty and stent implantation on QT dispersion |
Yazarlar: | Uludağ Üniversitesi/Tıp Fakültesi/Kardiyoloji Anabilim Dalı. 0000-0002-8974-8837 Yeşilbursa, Dilek Serdar, Akın Aydınlar, Ali AAI-6632-2021 36658194500 6603403111 6603131517 |
Anahtar kelimeler: | Cardiovascular system & cardiology QT dispersion Coronary angioplasty Stent implantation Acute myocardial-infarction Interval prolongation Sudden-death |
Yayın Tarihi: | 1999 |
Yayıncı: | Lippincott Williams & Wilkins |
Atıf: | Yeşilbursa, D. vd. (1999). "Effect of successful coronary angioplasty and stent implantation on QT dispersion". Coronary Artery Disease, 10(5), 335-337. |
Özet: | Background QT dispersion (defined as maximal QT interval minus minimal QT interval), as assessed using the surface EGG, has been shown to reflect regional inhomogeneities in ventricular repolarization. The aim of this study was to show the effect of coronary revascularization, by successful coronary angioplasty or stent implantation, on QT dispersion. Methods QT dispersion was defined on each ECG as the difference between the maximal and minimal measurements of QT interval. Of 135 patients studied, 52 patients underwent coronary angioplasty and 84 patients underwent stent implantation. Maximum and minimal QT interval and QT dispersion were measured using 12-lead electrocardiography before and 24 h after each successful procedure. Results QT dispersion decreased from 51 +/- 12 ms at baseline to 37 +/- 10 ms 24 after the procedure (P < 0.001). Before the procedure, the QT dispersion of patients undergoing angioplasty and stent implantation was 50 +/- 13 and 52 +/- 10 ms, respectively After the procedure, the QT dispersions were 34 +/- 9 and 38 +/- 10 ms, respectively (P<0.001). QT dispersion was significantly lower in both groups after the procedure, No differences were observed between the QT dispersions of patients undergoing angioplasty and of those undergoing stent implantation. Conclusions Successful coronary angioplasty and stent implantation significantly reduced QT dispersion. The decreased QT dispersion may have been caused by improvements in myocardial perfusion and may be beneficial in reducing the likelihood of arrhythmias occurring. |
URI: | https://doi.org/10.1097/00019501-199907000-00010 https://europepmc.org/article/med/10421974 https://journals.lww.com/coronary-artery/Abstract/1999/07000/Effect_of_successful_coronary_angioplasty_and.10.aspx http://hdl.handle.net/11452/21591 |
ISSN: | 0954-6928 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.