Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/22004
Başlık: Solar drying in sludge management in Turkey
Yazarlar: Uludağ Üniversitesi/Mühendislik Fakültesi/Çevre Mühendisliği Bölümü.
Salihoğlu, Nezih Kamil
Pınarlı, Vedat
Salihoğlu, Güray
AAG-9399-2021
AAG-9413-2021
8551769400
8551769100
8551769300
Anahtar kelimeler: Bursa [Turkey]
Bacteria
Dewatering
Coliform reduction
Solid wastes
Greenhouse
Temperature
Systems
Eurasia
Turkey
Net present value
Sludge management
Solar drying
Drying
Land fill
Sewage sludge
Science & technology-other topics
Energy & fuels
Yayın Tarihi: Ağu-2007
Yayıncı: Pergamon-Elsevier Science
Atıf: Salihoğlu, N. K. vd. (2007). "Solar drying in sludge management in Turkey". Renewable Energy, 32(10), 1661-1675.
Özet: Two main wastewater treatment plants in Bursa city in Turkey will start to operate and produce at least 27,000 tons of dry solids per year by the end of 2006. The purpose of this study was to investigate an economical solution to the sludge management problem that Bursa city would encounter. The general trend in Turkey is mechanical dewatering to obtain a dry solid (DS) content of 20%, and liming the mechanically dewatered sludge to reach the legal landfilling requirement, 35% DS content. This study recommends limited liming & solar drying as an alternative to only-liming the mechanically dewatered sludge. Open and covered solar sludge drying plants were constructed in pilot scale for experimental purposes. Dry solids and climatic conditions were constantly measured. Faecal coliform, reduction was also monitored. The specially designed covered solar drying plant proved to be more efficient than the open plant in terms of drying and faecal coliform reduction. It was found that, if the limited liming & solar drying method was applied after mechanical dewatering instead of only-liming method, the total amount of the sludge to be disposed would be reduced by approximately 40%. This would lead to a reduction in the transportation, handling, and landfilling costs. The covered drying system would amortize itself in 4 years.
URI: https://doi.org/10.1016/j.renene.2006.08.001
https://www.sciencedirect.com/science/article/pii/S096014810600228X
http://hdl.handle.net/11452/22004
ISSN: 09601481
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.


DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.