Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/22285
Başlık: | Real-time polymerase chain reaction for detection of mycoplasma gallisepticum in chicken trachea |
Yazarlar: | Uludağ Üniversitesi/Veteriner Fakültesi/Besin Hijyeni ve Teknolojisi Anabilim Dalı. Uludağ Üniversitesi/Veteriner Fakültesi/Mikrobiyoloji Anabilim Dalı. Çarlı, Kamil Tayfun Eyigör, Ayşegül AAI-1101-2021 6601971539 6602558950 |
Anahtar kelimeler: | Veterinary sciences Mycoplasma gallisepticum Poultry Real-time PCR Aves Bacteria (microorganisms) Gallus gallus Mycoplasma Tetrathionate broth enrichment Capillary PCR Diagnosis Synoviae DNA |
Yayın Tarihi: | Tem-2003 |
Yayıncı: | Amer Assoc Avian Pathologists |
Atıf: | Çarlı, K.T. ve Eyigör, A. (2003). “Real-time polymerase chain reaction for detection of mycoplasma gallisepticum in chicken trachea”. Avian Diseases, 47(3), 712-717. |
Özet: | In this work, we describe a rapid detection procedure for Mycoplasma gallisepticum from chicken tracheal swabs by real-time polymerase chain reaction (PCR) by LightCycler system, where we were able to monitor the amplification of the newly synthesized M gallisepticum-specific PCR product as a proportionally increasing fluorescent signal by using the double-stranded DNA binding dye SYBR Green I and have identified M. gallisepticum-specific PCR products by DNA melting curve analysis by plotting the first negative derivative (-d[F1]/dT) of fluorescence over temperature. Detection limits of the PCR were found to be 3 and 3000 colony-forming units ml(-1) with pure culture of M. gallisepticum and artificially spiked samples, respectively. Out of 96 tracheal swabs, 68 were taken from live chickens and 28 were taken by scraping the mucosal surface of the trachea (SMST) of necropsied chickens. All of the 18 PCR-positive results were from the swabs taken by the SMST method, whereas all of the samples taken from live chickens were negative. Thus, the PCR with the SMST method had a sensitivity and a specificity of 64.2% (18 of 28 chickens) and 100%, respectively. The total time required for template preparation from tracheal swab samples and real-time PCR was approximately 65 min. These results indicate that real-time PCR with the LightCycler technology is a rapid and sensitive test to identify M. gallisepticum-infected flocks if a proper sampling is applied. |
URI: | https://doi.org/10.1637/6041 http://hdl.handle.net/11452/22285 |
ISSN: | 0005-2086 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.