Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/22448
Başlık: An experimental study of bilateral repositioning of the Stensen's duct orifices with autologous vein and artery grafts in dogs
Yazarlar: Uludağ Üniversitesi/Tıp Fakültesi/Plastik ve Rekonstrüktif Cerrahi Anabilim Dalı/El Cerrahisi Bilim Dalı.
Uludağ Üniversitesi/Tıp Fakültesi/Histoloji ve Embriyoloji Anabilim Dalı.
0000-0003-0000-8355
Özgenel, Güzin Yeşim
Özcan, Mesut
Kahveci, Zeynep
AAH-4233-2021
6701823106
7102067678
6603395784
Anahtar kelimeler: Surgery
Sialorrhoea
Drooling
Stensen's duct repositioning
Vein graft
Dog
Artery graft
Surgical-management
Cerebral-palsy
Transposition
Ligation
Yayın Tarihi: 2000
Yayıncı: Churchill Livingstone
Atıf: Özgenel, G. Y. vd. (2000). "An experimental study of bilateral repositioning of the Stensen's duct orifices with autologous vein and artery grafts in dogs". British Journal of Plastic Surgery, 53(2), 106-108.
Özet: Sialorrhoea is an indication of dysfunction in the coordination of the swallowing mechanism. Disturbance in this coordination results in excess pooling of saliva in the anterior mouth and resultant drooling. Several surgical techniques have been described for the management of sialorrhoea. In this experimental study, we planned to try a more safe and physiologic technique by repositioning of the parotid duct orifices into the glossopalatal arch, using autologous free grafts of vein and artery in dogs. Ten adult dogs were used. In each dog, both of the parotid duct orifices were included in the study. The surgical procedure involved the dissection of both parotid duct orifices and their relocation via a submucosal tunnel into the glossopalatal arch, using a vein graft for the right side and an artery graft for the left side. Functional assessment was based on the clinical observations and retrograde sialography done on the 60th day. Results were excellent. No stricture or obstruction was noted. Histological examinations done on the 90th day showed the replacement of endothelium by multilayered cubic Stensen's duct epithelium in both artery and vein grafts. There was no difference between the results of artery and vein grafts. Surgical transposition of Stensen`s duct into the glossopalatal arch with autologous vein or artery graft is a safe technique which may be used in clinical cases of drooling us an alternative to the other techniques described.
URI: https://doi.org/10.1054/bjps.1999.3221
https://www.sciencedirect.com/science/article/pii/S0007122699932216
http://hdl.handle.net/11452/22448
ISSN: 0007-1226
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.


DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.