Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/22620
Başlık: Waste-heat recovery potential in Turkish textile industry: Case study for city of Bursa
Yazarlar: Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.
0000-0001-8022-1185
Pulat, Erhan
Etemoğlu, Akın Burak
Can, Muhiddin
ABE-9423-2020
23098080300
8221881000
7006114954
Anahtar kelimeler: Waste-heat recovery
Energy analysis
Exergy analysis
Economical analysis
Thermodynamic analysis
Entropy generation
Power-plants
Energy
Exchanger
Systems
Science & technology - other topics
Energy & fuels
Energy conversion
Energy management
Energy utilization
Exergy
Flow rate
Geothermal energy
Investments
Mass transfer
Pipe flow
Sewage
Textile industry
Textile processing
Textiles
Thermoanalysis
Waste heat
Wastewater
Water analysis
Case studies
Dyeing processes
Exergy destructions
Heat recovery systems
Inlet pressures
Inlet temperatures
Mass flow rates
PayBack Period (PBP)
Production capacities
System performances
Textile applications
Textile sectors
Tube heat exchangers
Turkish
Waste-heat recovery
Working conditions
Cooling water
Yayın Tarihi: Nis-2009
Yayıncı: Pergamon-Elsevier Science
Atıf: Pulat, E. vd. (2009). "Waste-heat recovery potential in Turkish textile industry: Case study for city of Bursa". Renewable & Sustainable Energy Reviews, 13(3), 663-672.
Özet: Textile sector of Turkey has a large production capacity and it is one of the important sectors. Many industrial heating processes generate waste energy in textile industry. Therefore, there is a tremendous waste-heat potential to utilize in textile applications. This study assesses the potential of waste-heat obtained from particularly dyeing process at textile industry in Bursa where textile center of Turkey. Energy consumptions could be decreased by using of waste-heat recovery systems (WHRSs). A thermodynamic analysis is performed in this study. An exergy-based approach is performed for optimizing the effective working conditions for WHRSs with water-to-water shell and tube heat exchanger. The payback period is found to be less than 6 months. The variations of the parameters which affect the system performance such as waste-water inlet temperature, mass flow rate, cooling water inlet pressure and dead state conditions are examined respectively. The results of the analysis show that the exergy destruction rate and economical profit increase with increasing of mass flow rate of the waste water. Similarly, exergy destruction rate, effectiveness and economical profit increase while the second law efficiency decreases as the waste-water inlet temperature increases.
URI: https://doi.org/10.1016/j.rser.2007.10.002
https://www.sciencedirect.com/science/article/pii/S1364032107001396
http://hdl.handle.net/11452/22620
ISSN: 1364-0321
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.


DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.