Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/23146
Başlık: | Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy |
Yazarlar: | Algın, Oktay Uludağ Üniversitesi/Tıp Fakültesi/Nöroradyoloji Anabilim Dalı. 0000-0002-3425-0740 Hakyemez, Bahattin Parlak, Müfit AAG-8521-2021 AAI-2318-2021 6602527239 7003589220 |
Anahtar kelimeler: | Neurosciences & neurology Radiology, nuclear medicine & medical imaging Hydrocephalus Magnetic resonance imaging MR cisternography PC cine MR Spontaneous third ventriculostomy Obstructive-hydrocephalus Dimeglumine Cysts |
Yayın Tarihi: | May-2011 |
Yayıncı: | Masson Editeur |
Atıf: | Algın, O. vd. (2011). "Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy". Journal of Neuroradiology, 38(2), 98-104. |
Özet: | Purpose. -To compare the diagnostic efficacies of phase-contrast MRI (PC-MRI) and three-dimensional constructive interference in steady-state (3D-CISS) sequence for the detection of spontaneous third ventriculostomy (STV) on the basis of contrast-enhanced MR cisternography (MRC). Patients and methods. -Eleven obstructive hydrocephalus patients with clinically-radiologically suspected STV and ten controls were examined by PC-MRI, 3D-CISS and MRC. PC-MRI and 3D-CISS sequence were applied to view the third ventricle and basal cisterns. Following injection of 0.5-1 ml intrathecal Gd-DTPA injection, postcontrast MRC images were obtained in three planes. Presence of STV was scored as follows: grade 0, no existence of STV; grade 1, STV present. Results of PC-MRI and 3D-CISS were compared with the MRC findings. Results. -In PC-MRI, five patients were assessed as grade 0 and six cases grade 1. As a result of 3D-CISS sequence, eight cases were evaluated as grade 0 and three cases grade 1. Based on MRC, nine cases were assessed as grade 0 and two cases grade 1. False positivity was found in four cases by PC-MRI and in one case by 3D-CISS. The sensitivity, specificity and accuracy of PC-MRI and 3D-CISS sequence regarding demonstration of STV, were 100, 100, 56, 89, 64, and 91% respectively. Discussion. -PC-MRI and 3D-CISS are helpful in confirming the STV. PC-MRI and 3D-CISS should be the first preference. If PC-MRI and 3D-CISS give negative results, then MRC is not required. MRC should be performed on patients who demonstrate suspected STV findings on PC-MRI and 3D-CISS sequences. MRC may prevent false positive results. |
URI: | https://www.sciencedirect.com/science/article/pii/S0150986110000854 https://doi.org/10.1016/j.neurad.2010.03.006 http://hdl.handle.net/11452/23146 |
ISSN: | 0150-9861 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.