Başlık: | The effects of colloid pre-loading on thromboelastography prior to caesarean delivery: Hydroxyethyl starch 130/0.4 versus succinylated gelatine |
Yazarlar: | Uludağ Üniversitesi/Tıp Fakültesi/Anesteziyoloji Anabilim Dalı. 0000-0002-6503-8232 0000-0002-3019-581X Türker, Gürkan Yılmazlar, Tijen Başaǧan, Elif Moğol Gurbet, Alp Dizman, S. Günay, H. AAI-6642-2021 A-7994-2018 7003400116 57212706402 23982134100 35618853300 37103707900 53363383400 |
Anahtar kelimeler: | Research & experimental medicine Pharmacology & pharmacy Colloid pre-loading Thromboelastography Caesarean section Spinal anaesthesia In-vitro Spinal-anesthesia Coagulation analysis Epidural-anesthesia Impair hemostasis Ringers solution Cardiac-surgery Section Hemodilution Hypotension |
Yayın Tarihi: | 2011 |
Yayıncı: | Sage Publications |
Atıf: | Türker, G. vd. (2011). "The effects of colloid pre-loading on thromboelastography prior to caesarean delivery: Hydroxyethyl starch 130/0.4 versus succinylated gelatine". Journal of International Medical Research, 39(1), 143-149. |
Özet: | This prospective, randomized, double-blind study compared the effects on thromboelastography (TEG) of pre-loading with two different colloid fluids prior to spinal anaesthesia for caesarean section. Healthy full-term parturients received either 500 ml 6% hydroxyethyl starch 130/0.4 (HES, n = 25) or 500 ml 4% succinylated gelatine (GEL, n = 25) prior to spinal anaesthesia. TEG parameters including reaction time (r-time), clot formation time (k-time), clot formation rate (alpha-angle) and maximum amplitude (MA) were measured immediately before and after pre-loading. Both groups had significantly shorter r-time and lower MA after pre-loading. The a-angle was significantly decreased after pre-loading with HES but not with GEL. No significant differences in k-time were induced pre-loading. In conclusion, pre-loading with HES or GEL was associated with a mild hypocoagulable effect in healthy parturients presenting for elective caesarean section; however, all TEG parameters in both groups remained within or very close to the normal range after pre-loading. |
URI: | https://journals.sagepub.com/doi/10.1177/147323001103900115 https://doi.org/10.1177/147323001103900115 http://hdl.handle.net/11452/23581 |
ISSN: | 0300-0605 1473-2300 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Dosya | Açıklama | Boyut | Biçim | |
---|---|---|---|---|
Türker_vd_2011.pdf | 101.39 kB | Adobe PDF | Göster/Aç |
Bu öğe kapsamında lisanslı Creative Commons License