Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/24063
Başlık: | Oxygen uptake kinetics during incremental- and decremental-ramp cycle ergometry |
Yazarlar: | Rossiter, Harry B. Ward, Susan A. Whipp, Brian J. Uludağ Üniversitesi/Tıp Fakültesi/Fizyoloji Anabilim Dalı. 0000-0002-4606-6596 Özyener, Fadil AAH-1641-2021 6506242143 |
Anahtar kelimeler: | Sport sciences Oxygen uptake-work rate gain Incremental-ramp exercise Decremental-ramp exercise System linearity Slow component Gas-exchange Heavy exercise Muscle-fibers Load exercise Humans Fatigue Tests Transients Parameters |
Yayın Tarihi: | Eyl-2011 |
Yayıncı: | Journal Sport Science and Medicine |
Atıf: | Özyener, F. vd. (2011). "Oxygen uptake kinetics during incremental- and decremental-ramp cycle ergometry". Journal of Sports Science and Medicine, 10(3), 584-589. |
Özet: | The pulmonary oxygen uptake (VO2) response to incremental-ramp cycle ergometry typically demonstrates lagged-linear first-order kinetics with a slope of similar to 10-11 ml.min(-1).W-1, both above and below the lactate threshold (theta(L)), i.e. there is no discernible VO2 slow component (or "excess" VO2) above theta(L). We were interested in determining whether a reverse ramp profile would yield the same response dynamics. Ten healthy males performed a maximum incremental -ramp (15-30 W.min(-1), depending on fitness). On another day, the work rate (WR) was increased abruptly to the incremental maximum and then decremented at the same rate of 15-30 W. min(-1) (step-decremental ramp). Five subjects also performed a sub-maximal ramp-decremental test from 90% of theta(L). VO2 was determined breath-by-breath from continuous monitoring of respired volumes (turbine) and gas concentrations (mass spectrometer). The incremental-ramp VO2-WR slope was 10.3 +/- 0.7 ml.min(-1).W-1, whereas that of the descending limb of the decremental ramp was 14.2 +/- 1.1 ml.min(-1).W-1 (p < 0.005). The sub-maximal decremental-ramp slope, however, was only 9.8 +/- 0.9 ml.min(-1).W-1: not significantly different from that of the incremental-ramp. This suggests that the VO2 response in the supra-theta(L) domain of incremental-ramp exercise manifest not actual, but pseudo, first-order kinetics. |
URI: | https://pubmed.ncbi.nlm.nih.gov/24150637/ http://hdl.handle.net/11452/24063 |
ISSN: | 1303-2968 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.