Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/24641
Başlık: | Cuffed oropharyngeal airway as a suitable alternative to the laryngeal mask airway for minor outpatient surgery |
Yazarlar: | Acar, H. Volkan Uludağ Üniversitesi/Tıp Fakültesi/Anesteziyoloji Anabilim Dalı. Yavaşçaoğlu, Belgin Kahveci, Ferda Kaya, Fatmanur Nazlı Dinçer Özcan, Bahar AAI-7914-2021 AAG-9356-2021 AAI-8213-2021 6602742300 6602405968 7003619647 6603825848 |
Anahtar kelimeler: | Cuffed oropharyngeal airway Intratracheal Intubation Laryngeal mask airway Copa Anesthesia Management Adjunct |
Yayın Tarihi: | Mar-2002 |
Yayıncı: | Lippincott Williams & Wilkins |
Atıf: | Yavaşçaoğlu, B. vd. (2002). "Cuffed oropharyngeal airway as a suitable alternative to the laryngeal mask airway for minor outpatient surgery". European Journal of Anaesthesiology, 19(3),203-207. |
Özet: | Background and objective: To compare the application of the cuffed oropharyngeal airway and the laryngeal mask airway on anaesthetized adult patients undergoing minor outpatient surgery. Methods: One hundred patients received intravenous fentanyl, propofol and N2O for the induction and maintenance of anaesthesia. The patients were randomly divided into two groups: a cuffed oropharyngeal airway group (n = 50) and a laryngeal mask airway group (n = 50). After insertion of the device, fibreoptic laryngoscopy was attempted and the degree of success scored. We then compared the first application success rate of both procedures while judging airway intervention requirement, fibreoptic scores, adverse airway events and haemodynamic tolerance. Results: Both devices had an almost similar first-time placement rate (cuffed oropharyngeal airway 84% versus laryngeal mask airway 96%). The cuffed oropharyngeal airway required a higher number of airway interventions (P < 0.001). The laryngeal mask airway had a significantly better fibreoptic view compared with the cuffed oropharyngeal airway (P < 0.001). However, the number of adverse airway events was lower in the cuffed oropharyngeal airway group; there were no significant differences in adverse events and haemodynamic variables between the said two groups. Conclusions: The results suggest that the cuffed oropharyngeal airway was an effective alternative airway in spontaneously breathing patients during short procedures. |
URI: | https://doi.org/10.1017/S0265021502000364 https://www.cambridge.org/core/journals/european-journal-of-anaesthesiology/article/abs/cuffed-oropharyngeal-airway-as-a-suitable-alternative-to-the-laryngeal-mask-airway-for-minor-outpatient-surgery/6316B82DA8D6917AEA16CDFB02A167FD http://hdl.handle.net/11452/24641 |
ISSN: | 0265-0215 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.