Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/25276
Title: | Chemical shift MRI: Is there any contribution to morphologic evaluation of solid breast masses? |
Authors: | Uludağ Üniversitesi/Tıp Fakültesi/Radyoloji Anabilim Dalı. Uludağ Üniversitesi/Tıp Fakültesi/Biyoistatistik Anabilim Dalı. 0000-0002-3238-9554 0000-0002-2382-290X Gökalp, Gökhan Topal, Uğur Bolca, Naile Bolca Ercan, İlker AAI-2336-2021 8312505100 57001254100 13806674200 6603789069 |
Keywords: | Breast Chemical shift Margin Mass Interpretation model Bi-rads Subtraction Lesions Malignancies Sonography Diagnosis Tumors Phase Radiology, nuclear medicine & medical imaging |
Issue Date: | Oct-2009 |
Publisher: | Elsevier Science |
Citation: | Gökalp, G. vd. (2009). "Chemical shift MRI: Is there any contribution to morphologic evaluation of solid breast masses?". Academic Radiology, 16(10), 1263-1271. |
Abstract: | Rationale and Objectives. To investigate the contribution of chemical shift magnetic resonance imaging for assessment of the margins of solid breast masses by benefiting from India ink artifact. Methods and Materials. Eighty-eight masses in 64 patients were evaluated in T1- and T2-weighted images, dynamic contrast and chemical shift studies according to Breast Imaging Reporting and Data System magnetic resonance lexicon. Subtraction images were automatically obtained by chemical shift imaging and dynamic studies. Each Sequence was scored using a scale of 1 to 5 according to its ability to demonstrate mar ins separate from surrounding parenchyma. Breast parenchyma was evaluated as fatty and dense. The results were compared with the histopathologic results. Results. Twenty-eight (31.8%) of the lesions were localized in fatty breast, and the remaining 60 (68.2%) lesions were localized in dense breast. There were 34 (38.6%) benign and 54 (61.4%) malignant masses. In fatty breast, chemical shift subtraction and T1-weighted images were valuable both for the demonstration and differentiation of benign lesions (P < .05). None of the sequence was valuable for both the demonstration and differentiation of malignant lesions in fatty breasts (P > .05). In dense breasts, chemical shift subtraction and dynamic contrast Subtraction images were valuable for both the demonstration and differentiation of benign and malignant lesions. Additional to these sequences, T2-weighted images was also valuable for benign lesions (P < .05). Conclusion. Chemical shift subtraction call contribute to routine dynamic contrast subtraction in morphologic analysis particularly for the evaluation of margins of benign lesions in fatty breasts. It can also help in morphologic analysis of masses in dense breast. |
URI: | https://doi.org/10.1016/j.acra.2009.05.014 https://www.sciencedirect.com/science/article/abs/pii/S1076633209003134 http://hdl.handle.net/11452/25276 |
ISSN: | 1076-6332 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.