Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/25744
Başlık: | The effect of catheter use on vein grafting of a peripheral nerve defect: An experimental study |
Diğer Başlıklar: | Ven grefti ile periferik sinir defektlerinin onarımında kateter kullanımının sinir rejenerasyonuna etkisi: Deneysel çalışma |
Yazarlar: | Bayraktar, Alper Mehmet Uludağ Üniversitesi/Tıp Fakültesi/Plastik ve Rekonstrüktif Cerrahi Anabilim Dalı. Uludağ Üniversitesi/Tıp Fakültesi/Fizyoloji Anabilim Dalı. Uludağ Üniversitesi/Tıp Fakültesi/Histoloji Anabilim Dalı. Özbek, Serhat Özcan, Mesut Noyan, Behzat Çavuşoğlu, İlkin AAH-5441-2021 7005245657 7102067678 6506333172 6602910240 |
Anahtar kelimeler: | Emergency medicine Peripheral nerve injury Nerve defect Vein graft Sciatic function index To-side neurorrhaphy Functional-evaluation Muscle grafts Regeneration Repair Rat Conduit Interposition Transection Periferik sinir yaralanması Sinir hasarı Ven grefti |
Yayın Tarihi: | Eyl-2012 |
Yayıncı: | Türk Travma ve Acil Cerrahi Derneği |
Atıf: | Bayraktar, A. M. vd. (2012). "The effect of catheter use on vein grafting of a peripheral nerve defect: An experimental study". Ulusal Travma ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery, 18(5), 367-375. |
Özet: | BACKGROUND: Since vein grafts have been used in the repair of nerve defects, studies regarding this procedure have accumulated, and after coming into clinical use, it was noticed that there is a problem of collapse in the vein graft. METHODS: Forty Sprague-Dawley rats were used, divided into five groups. No surgical intervention was performed in the first group. The defect was created in the sciatic nerve in Group 2 and left unrepaired. In Group 3, the defect was repaired with a nerve graft. In Group 4, the defect was repaired with a vein graft, while in Group 5, the repair was performed using a vein graft with an inserted catheter. In order to evaluate functional recovery and nerve regeneration, walking track analysis, electrophysiologic and histomorphometric analyses were done at the end of the 12th week. RESULTS: Although there were no functional differences between Groups 5 and 4, comparisons regarding nerve conduction velocity demonstrated that the results obtained in Group 5 were better than those in Group 4. When the number of axons on the distal part of the sciatic nerve and mid-segment of the repaired area was taken into account, no significant difference was found between Groups 3 and 5, whereas there was a significant difference between Groups 4 and 5. CONCLUSION: In our study, it was experimentally shown that the problem of collapse of a vein graft occurring after its use in the reconstruction of a nerve defect can be overcome by placing a catheter into the vein graft. Consequently, this method may eliminate the need for the use of a nerve graft in selected cases. |
URI: | https://doi.org/10.5505/tjtes.2012.59932 https://tjtes.org/jvi.aspx?pdir=travma&plng=eng&un=UTD-59932 https://www.journalagent.com/z4/jvi.asp?pdir=travma&plng=tur&volume=18&issue=5 http://hdl.handle.net/11452/25744 |
ISSN: | 1306-696X |
Koleksiyonlarda Görünür: | Scopus TrDizin Web of Science |
Bu öğenin dosyaları:
Dosya | Açıklama | Boyut | Biçim | |
---|---|---|---|---|
Özbek_vd_2012.pdf | 2.72 MB | Adobe PDF | Göster/Aç |
Bu öğe kapsamında lisanslı Creative Commons License