Title: | Experimental and numerical investigation of pressure drop coefficient and static pressure difference in a tangential inlet cyclone separator |
Authors: | Kaya, Fuat Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü. Karagöz, İrfan AAB-9388-2020 56785809700 |
Keywords: | Chemistry Swirling flows Cfd Pressure drop Pressure drop coefficient Particle flow Gas cyclone Performance Collection |
Issue Date: | Nov-2012 |
Publisher: | Springer |
Citation: | Kaya, F. ve Karagöz, İ. (2012). "Experimental and numerical investigation of pressure drop coefficient and static pressure difference in a tangential inlet cyclone separator". Chemical Papers, 66(11), 1019-1025. |
Abstract: | The aim of this study was to investigate the pressure drop coefficient and the static pressure difference related to the natural vortex length and to evaluate the results for gas-particle applications. CFD simulations were carried out using a numerical technique which had been verified previously. Results obtained from the numerical simulations were compared with the experimental data. Analysis of the results showed that the pressure drop coefficient decreases with the increasing inlet velocity, becoming almost constant above a certain value of the inlet velocity. The reason is that the effect of viscous forces decreases at high Reynolds numbers. The pressure drop coefficient also decreases with the increasing exit pipe diameter and decreasing exit pipe length. |
URI: | https://doi.org/10.2478/s11696-012-0214-7 https://www.degruyter.com/document/doi/10.2478/s11696-012-0214-7/html http://hdl.handle.net/11452/26618 |
ISSN: | 0366-6352 1336-9075 |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.