Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/28193
Başlık: | Posterior iris fixation of the iris-claw intraocular lens implantation through a scleral tunnel incision |
Yazarlar: | Uludağ Üniversitesi/Tıp Fakültesi/Oftalmoloji Bölümü. Baykara, Mehmet Özçetin, Hikmet Yılmaz, Sami Timuçin, Özgür Bülent ABI-7051-2020 AAJ-9038-2020 23093006700 6603402155 21744031100 25959383900 |
Anahtar kelimeler: | Loop anterior-chamber Capsular support Follow-up Absence Children Myopia |
Yayın Tarihi: | Eki-2007 |
Yayıncı: | Elsevier Science |
Atıf: | Baykara, M. vd. (2007). "Posterior iris fixation of the iris-claw intraocular lens implantation through a scleral tunnel incision". American Journal of Ophthalmology, 144(4), 586-591. |
Özet: | PURPOSE: To evaluate the technique, efficacy, and safety of posterior iris fixation of iris-claw intraocular lens (IOLs) implantation through a scleral tunnel incision for aphakia correction. DESIGN: Noncomparative, interventional case series. METHODS: A secondary posterior iris fixation of the Artisan iris-claw IOL (Ophthec BV, Groningen, The Netherlands) was implanted for aphakia correction in the authors' clinical practice. Uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), astigmatism, manifest refraction, lens position, pigment dispersion, and intraocular pressure (IOP) were evaluated in 32 consecutive eyes of 32 patients. RESULTS: BSCVA was 20/40 or better in 28 eyes (87.50%) during the mean follow,up time (nine months). Mean postoperative spherical equivalent was -0.70 diopters (D; standard deviation [SD], 0.47 D) at six months after surgery. Mean prediction error was -0.13 D (SD, 0.28 D), and mean absolute prediction error was 0.26 D (SD, 0.15 D). Preoperative mean astigmatism was -1.08 D (SD, 0.55 D; range, 0.0 to -2.0 D). At six months after surgery, mean astigmatism was -2.1 D (SD, 0.81 D; range, -0.75 to -3.75 D). There was no significant postoperative IOP increase. Lens position, evaluated by Oculus Pentacam (Pentacam 70700: Oculus, Wetzlar, Germany) and ultrasound biomicroscopy [UBM] (Ophthalmic Technologies Inc, Toronto, Ontario, Canada), was parallel to the iris plane. CONCLUSIONS: Posterior iris fixation of the iris claw IOL implantation through a scleral tunnel incision is a safe procedure and an effective option for aphakic eyes without capsule support. |
URI: | https://doi.org/10.1016/j.ajo.2007.06.009 https://www.sciencedirect.com/science/article/pii/S0002939407005296 http://hdl.handle.net/11452/28193 |
ISSN: | 0002-9394 |
Koleksiyonlarda Görünür: | PubMed Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.