Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/28195
Başlık: | Context sensitive links 1 of 1 fast determination of octinoxate and oxybenzone uv filters in swimming pool waters by gas chromatography/mass spectrometry after solid-phase microextraction |
Yazarlar: | Kanakaki, C. Rosenberg, Erwin Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü. 0000-0002-1074-3612 Yılmazcan, Özlem İzgi, Belgin AAE-8564-2020 57494368900 8130734000 |
Anahtar kelimeler: | Low-pressure gas chromatography Mass spectrometry Octinoxate Oxybenzone Solid-phase microextraction Swimming pool water Bar sorptive extraction Ultraviolet filters Bathing waters Recent trends Samples Benzophenone Optimization Configurations Sunscreens Chemistry Endocrine disrupters Gas chromatography Lakes Swimming pools Uncertainty analysis Low-pressure gas chromatography Extraction |
Yayın Tarihi: | Tem-2015 |
Yayıncı: | Wiley |
Atıf: | Yılmazcan, Ö. vd. (2015). "Context sensitive links 1 of 1 fast determination of octinoxate and oxybenzone uv filters in swimming pool waters by gas chromatography/mass spectrometry after solid-phase microextraction". Journal of Separation Science, 38(13), 2286-2297. |
Özet: | A fast gas chromatography/mass spectrometry method was developed and validated for the analysis of the potential endocrine disrupters octinoxate and oxybenzone in swimming pool water samples based on the solvent-free solid-phase microextraction technique. The low-pressure gas chromatography/mass spectrometry method used for the fast identification of UV filter substances was compared to a conventional method in terms of sensitivity and speed. The fast method proposed resulted in 2 min runs, leading to an eightfold decrease in the total analysis time and a sevenfold improvement in detection limits. The main parameters affecting the solid-phase microextraction process were also studied in detail and the optimized conditions were as follows: fiber coating, polyacrylate; extraction mode, direct immersion; extraction temperature, 25 degrees C; sample volume, 5 mL; extraction time 45 min; pH 6.5. Under the optimized conditions, a linear response was obtained in the concentration range of 0.5-25 mu g/L with correlation coefficients in the range 0.990-0.999. The limits of detection were 0.17-0.29 mu g/L, and the recoveries were 80-83%. Combined method uncertainty was assessed and found to be less than 7% for both analytes for concentrations equal to or higher than 5 mu g/L. Pool water samples were analyzed to demonstrate the applicability of the proposed method. Neither octinoxate nor oxybenzone were detected in the swimming pool water samples at concentrations above the respective limits of detection. |
URI: | https://doi.org/10.1002/jssc.201401250 https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.201401250 http://hdl.handle.net/11452/28195 |
ISSN: | 1615-9306 1615-9314 |
Koleksiyonlarda Görünür: | Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.