Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/28555
Başlık: Performance analysis of a two stage pad cooling system in broiler houses
Yazarlar: Uludağ Üniversitesi/Veteriner Fakültesi/Zootekni Bölümü.
0000-0003-4560-2438
0000-0002-5611-4993
0000-0002-4046-3291
Petek, Metin
Dikmen, Serdal
Oğan, Mehmet Mustafa
A-5731-2018
AFC-4794-2022
7004448692
8280302600
24335609900
Anahtar kelimeler: Veterinary sciences
Broiler house
Pad cooling
Performance
Increasing air velocities
Temperatures
Environment
Responses
Yayın Tarihi: 2012
Yayıncı: TÜBİTAK
Atıf: Petek, M. vd. (2012). "Performance analysis of a two stage pad cooling system in broiler houses". Turkish Journal of Veterinary and Animal Sciences, 36(1), 21-26.
Özet: The cooling performance of a traditional (control) and two stage evaporative pad cooling system (experiment), including pad and fan with tunnel ventilation, for poultry houses and the growth performance of broilers reared in these systems was compared in a study performed during extreme summer temperatures. The experimental unit had a two stage pad cooling system, which consisted of underground tubes and a box, followed by a pad cooling system with tunnel ventilation. The control unit had a traditional evaporative cooling system, including pad and fan with tunnel ventilation. Air temperature, relative humidity, and saturation efficiency were used to determine the cooling performance of the systems. Live body weight gain, feed conversion ratio, and mortality rate were used to monitor the growth performance of broilers raised in these systems. The air temperature and relative humidity of incoming house and exhausted air in the two stage pad cooling system were found to be significantly lower than those of the traditional system (P < 0.05). The cooling efficiency or saturation efficiency in the two stage cooling system was found to be slightly greater than that of the traditional system. Body weight gain was also significantly influenced by the cooling system (P < 0.05). The results indicated that two stage pad cooling is a more efficient method to alleviate heat stress in broilers during heat stress conditions and to improve growth performance.
URI: https://doi.org/10.3906/vet-1101-755
https://journals.tubitak.gov.tr/veterinary/vol36/iss1/4/
http://hdl.handle.net/11452/28555
ISSN: 1300-0128
Koleksiyonlarda Görünür:Scopus
TrDizin
Web of Science

Bu öğenin dosyaları:
Dosya Açıklama BoyutBiçim 
Petek_vd_2012.pdf255.35 kBAdobe PDFKüçük resim
Göster/Aç


Bu öğe kapsamında lisanslı Creative Commons License Creative Commons