Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/29100
Başlık: Effects of temporary vascular occluder poloxamer 407 Gel on the endothelium
Yazarlar: Gücü, Arif
Eriş, Cüneyt
Toktaş, Faruk
Göncü, Tuǧrul
Özyazıcıoğlu, Ahmet Fatih
Uludağ Üniversitesi/Tıp Fakültesi/Histoloji ve Embriyoloji Anabilim Dalı.
Çavuşoǧlu, İlkin
6602910240
Anahtar kelimeler: Cardiovascular system & cardiology
Surgery
Endothelial damage
Poloxamer 407
Scanning electron microscopy
OPCAB
Coronary-artery occlusion
Intracoronary shun
Dysfunction
Injury
Damage
Yayın Tarihi: 22-Oca-2013
Yayıncı: BMC
Atıf: Gücü, A. vd. (2013). "Effects of temporary vascular occluder poloxamer 407 Gel on the endothelium". Journal of Cardiothoracic Surgery, 8(1).
Özet: Background: Coronary occlusion techniques during OPCAB may lead to an endothelial damage to the target vessel. The adverse effects of these techniques are well-known, and researches have been trying to find out new materials to occlude the coronary artery without an endothelial damage. In the present study, we investigate to the endothelial damage in the rat aorta which is occluded by Poloxamer 407 gel. Methods: Forty-five rats were randomized in three groups: (1) segment of the aorta was occluded with Poloxamer 407 gel in P 407 group; (2) segment of the aorta was occluded with microvascular clamp in MV clamp group; and (3) no onclusion was available in the Control group. The rats were sacrificed of observation, and a 15mm segment of the aorta was obtained as a specimen. Integrity of the endothelial lining was observed with a scanning electron microscopy. Results: Scanning electron microscopy revealed a statistically significant difference among the 3 groups (p<0,001) using the SPSS 13.0 test. No difference was found between the Control group and the P 407 group (p=0,059). The differences between MV clamp-Control group (p<0,001) and MV clamp-P 407 group were statistically significant (p<0,002). Conclusions: We suggest that Poloxamer 407 gel occlusion may be a safer and more effective method compared to the microvascular clamp occlusion.
URI: https://doi.org/10.1186/1749-8090-8-16
https://cardiothoracicsurgery.biomedcentral.com/articles/10.1186/1749-8090-8-16
http://hdl.handle.net/11452/29100
ISSN: 1749-8090
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Dosya Açıklama BoyutBiçim 
Çavuşoğlu_vd_2013.pdf1.79 MBAdobe PDFKüçük resim
Göster/Aç


Bu öğe kapsamında lisanslı Creative Commons License Creative Commons