Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/29189
Başlık: | Sutureless vascular anastomoses by N-butyl-2 cyanoacrylate adhesive: An experimental animal study |
Yazarlar: | Uludağ Üniversitesi/Tıp Fakültesi/Kardiyovasküler Cerrahi Anabilim Dalı. Uludağ Üniversitesi/Tıp Fakültesi/Embriyoloji Anabilim Dalı. Saba, Davit Yılmaz, M. Yavuz, Hanife Noyan, Sema Avcı, Berrin Ercan, Akbay Özkan, Hicran Dönmez Cengiz, Murad ABE-6685-2020 6603339291 57220839864 57214619019 56636269700 6603017388 55398003800 7103355993 7003766367 |
Anahtar kelimeler: | Surgery N-butyl-2-cyanoacrylate Polytetrafluoroethylene Sutureless anastomoses Octylcyanoacrylate tissue adhesive Microvasculae anstomosis Clinical applications Surgery Closure Glue Arteries |
Yayın Tarihi: | 2007 |
Yayıncı: | Karger |
Atıf: | Saba, D. vd. (2007). "Sutureless vascular anastomoses by N-butyl-2 cyanoacrylate adhesive: An experimental animal study". European Surgical Research, 39(4), 239-244. |
Özet: | Background: The purpose of this animal study was to find out whether sutureless anastomoses using N-butyl-2-cyanoacrylate were effective in the suppression of neointimal hyperplasia or not. Material and Methods: Ten male adult mongrel dogs were used in this animal study. The animals were randomly divided into a control group (n = 5) and a study group (n = 5). The study group underwent sutureless anastomoses using N-buthyl-2-cyanoacrylate adhesive. Infrarenal aortoaortic graft was interposed using polytetrafluoroethylene. Results: In the study group, the mean intimal thickness at the proximal anastomosis was 27.4 ± 1.94 μm and 27.4 ± 1.51 μm at the distal anastomosis. In the control group, the mean intimal thickness was 138.4 ± 5.02 μm at the proximal anastomosis and 67.6 ± 6.42 μm at the distal anastomosis. Intimal thickness at the proximal and distal anastomoses in the control group was significantly (p < 0.001) greater than in the study group. Also, perianastomotic inflammation was more obvious in the control group compared to the study group (p < 0.01). Conclusion: Sutureless anastomoses using with N-butyl-2-cyanoacrylate adhesive might be a good alternative to conventional suture technique. |
URI: | https://doi.org/10.1159/000101893 https://www.karger.com/Article/Abstract/101893 http://hdl.handle.net/11452/29189 |
ISSN: | 0014-312X 1421-9921 |
Koleksiyonlarda Görünür: | PubMed Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.